Handling

The Cello 6S is sensitive electronic equipment and as such must be handled with care and consideration. Sudden
impact(s) may adversely affect product operation and / or structural integrity and will therefore invalidate all applicable
warranties.

Cleaning

The Cello 6S enclosure is only to be cleaned using clean water and a clean cloth. Do not use any solvent(s) or
detergent(s) as these may adversely affect the integrity of the enclosure.

Lithium battery packs / cells

Use only battery packs specifically approved by Technolog for use with Cello 6S 'water'. Store battery packs / cells in
their original packaging, do not store in direct sun light, do not store on or close to bare metal, avoid short circuiting cells
/ battery packs and do not make contact with the terminals.

Under normal conditions lithium battery packs / cells are safe however they must be handled and treated with care. Do
not mistreat or abuse battery packs / cells. Do not drop, open, puncture, heat, attempt to recharge, expose contents to
water, dispose of in fire or short circuit battery packs / cells. Do not weld or solder to the cell body. Mistreated battery
packs / cells can cause fire or explosion and are potentially a severe burn hazard. The cell contents are harmful by
ingestion, inhalation, skin contact, cause headache, dizziness, nausea and prolonged exposure may result in liver
damage whilst the vapour is narcotic in high concentrations.

Spent batteries must not be disposed of as unsorted municiple waste but collected separately in order to allow correct
environmentally sound treatment and recycling. Where possible battery packs / cells should be returned either to
Technolog or their authorised agents however where this is not possible, prior to disposal your local waste disposal
authority should be contacted regarding any regulations in force at the time concerning waste disposal procedures in
relation to lithium / thionyl chloride inorganic electrolyte battery packs / cells. Refer to the cell manufacturer's "Control of
Substances Hazardous to Health (COSHH)" information, available from Technolog, for further details of cell safe use and
disposal guidelines.

Disposal / end of life

The Cello 6S is electrical / electronic equipment and as such, at end of life, it must not be disposed of as unsorted
municiple waste but collected separately in order to allow correct and environmentally sound treatment and recycling.
Where possible Cello 6S should be returned either to Technolog or their authorised agents however where this is not
possible, prior to disposal your local waste disposal authority should be contacted regarding any regulations in force at the
time concerning waste disposal procedures in relation to waste electrical and / electronic equipment. Refer also to
precautions in relation to lithium battery packs / cells above.

Precautions

Содержание Cello 6S

Страница 1: ...ights reserved Information contained in this document subject to change without prior notice Sheet 1 of 41 Technolog Limited Ravenstor Road Wirksworth DE4 4FY United Kingdom T 44 0 1629 823611 E techn...

Страница 2: ...el configuration 19 Installation Commissioning Cello 6 Wizard Setting the time 20 Installation Commissioning Cello 6 Wizard Meter settings 23 Installation Commissioning Cello 6 Wizard Alarm settings G...

Страница 3: ...r 3G UMTS mobile telecommunications networks Environment The Cello 6S water is specifically for use in non hazardous indoor and outdoor locations both above and below ground in ambient temperatures in...

Страница 4: ...plosion and are potentially a severe burn hazard The cell contents are harmful by ingestion inhalation skin contact cause headache dizziness nausea and prolonged exposure may result in liver damage wh...

Страница 5: ...curity tag s Local communications COMMs connection Option Input cable Mil Spec compatible MC03 connector termination Recess for fitting of optional user label Option Input cable un terminated flying l...

Страница 6: ...prior notice Sheet 6 of 41 Technolog Limited Ravenstor Road Wirksworth DE4 4FY United Kingdom T 44 0 1629 823611 E technolog technolog com www technolog com DMR No 7311 2137PM9001 Rev A Features cont...

Страница 7: ...s document subject to change without prior notice Sheet 7 of 41 Technolog Limited Ravenstor Road Wirksworth DE4 4FY United Kingdom T 44 0 1629 823611 E technolog technolog com www technolog com DMR No...

Страница 8: ...that the necessary permissions are in place to allow entry before proceeding Be aware that to prevent the ingress of moisture and debris the lid must not be left off for any longer than is absolutely...

Страница 9: ...ironment by suitably trained competent personnel in accordance with the applicable code s of practice Step 1 Ensure the gasket seal is clean un damaged and is in good condition clean and or replace wh...

Страница 10: ...Noting orientation for replacement re fitting carefully remove the SIM card taking care not to catch the PCB mounted antenna where fitted Step 4 When re fiiting the SIM card ensure that it is clean an...

Страница 11: ...tep 2 Attach a Technolog Fast Barrier Unit FBU complete with either a CBLBS04P000 x or CBLBS04P001 x output cable to the COMMs connector Step 1 Remove the protective cap from the local communications...

Страница 12: ...type i e connector or flying lead the inputs may be connected to other equipment that provides a volt free output either in the form of switch closure or open collector The maximum frequency that may...

Страница 13: ...nnected Contact Technolog for further infomation and details of antennas that are already approved for use with Cello 6S Use of any un approved external antenna with Cello 6S could lead to a potential...

Страница 14: ...f this manual It also to be ensured that the computer laptop tablet you are using has the latest release of Technolog Cello 6 Wizard software installed contact Technolog for details and that it has be...

Страница 15: ...nstallation Commissioning Cello 6 Wizard Startup Commissioning process Step 1 Select the Cello 6 Wizard icon on your PC laptop tablet Step 2 Once you have selected the software the software s Welcome...

Страница 16: ...gnal strength On the display you will see the cellular network s detected by the modem with the strongest base station readings first with the readings being updated approximately every five seconds u...

Страница 17: ...lue Where the Cello 6S has the FLxm RSD flying lead input output cable option fitted then a replication of the inputs applied at channel 1 Ch1 may be output refer to the Installation Standard connecti...

Страница 18: ...e instructed to either send only that day s daily index reading by ticking the Send today s meter reading box or to send all daily index readings since the last successful data send by ticking the Sen...

Страница 19: ...ablet being used to setup the Cello 6S as well as the time and date and the date and time already setup in the Cello 6S already setup in the Cello 6S itself If the time and or date of the two clocks a...

Страница 20: ...2137PM9001 Rev A Installation Commissioning Cello 6 Wizard Meter settings Step 8 Meter settings The initial Meter settings page is now displayed although the content will depend on the options selecte...

Страница 21: ...ding all alphanumeric characters of the meter attached to the Pulse inputs of the Cello 6S in the Meter 1 text box this box can accept up to 13 characters Typically the meter outputs one pulse for a g...

Страница 22: ...of this manual type the full serial number including all alphanumeric characters of the meter attached to the Tamper inputs of the Cello 6S in the Meter 2 text box this box can accept up to 13 charact...

Страница 23: ...General Step 9 Alarm settings The Cello 6S has a choice of two different alarm types Flow high low alarms Daily usage high low alarms Any channel s enabled at the Installation Commissioning Cello 6 Wi...

Страница 24: ...ted whilst ever the flow rate is exceeded A set high value Currently High and or where there is a normal to high transition in the flow rate Normal High and or where there is a high to low transition...

Страница 25: ...com DMR No 7311 2137PM9001 Rev A Where the Daily usage alarm type is selected type the required high low limits in the text boxes provided note the values can also be increased decreased using the up...

Страница 26: ...Road Wirksworth DE4 4FY United Kingdom T 44 0 1629 823611 E technolog technolog com www technolog com DMR No 7311 2137PM9001 Rev A Installation Commissioning Cello 6 Wizard Alarm settings Finalising U...

Страница 27: ...Service Limited UDSL Technolog Message Service Centre TMSC is shown Review the fields and when they are are set as required select Next Where GPRS communication is required first select the GPRS opti...

Страница 28: ...d that the telephone number of the Cello 6S is sent as the identifier then the Use Default Values box is to be ticked Where this option is selected all remaining fields will be greyed out and not acce...

Страница 29: ...l not be greyed out in the SMS Number field Regardless of configuration the telephone number of the fitted SIM card is entered in full including international code is automatically entered by the Cell...

Страница 30: ...is required that even though the Cello 6S will only send its data weekly by clicking the Daily Wakeup box it will wake up and listen for any SMS configuration messages being sent to it thereby allowin...

Страница 31: ...will only send its date weekly by clicking the Daily Wakeup box it will wake up and listen for any SMS configuration messages being sent to it thereby allowing remote over the air setup and changes t...

Страница 32: ...per day at 6am However this option is programmable by Technolog either at the factory during manufacture or remotely once installed although when programmed its name will change to whatever has been r...

Страница 33: ...lo 6 Wizard Dialout settings Finalising Review the allocated Dialout settings and when they are set as required select Next Step 13 Finish All configurable options should now have been set as required...

Страница 34: ...311 2137PM9001 Rev A Installation Commissioning Cello 6 Wizard Finishing Step 13 Finish All configurable options should now have been set as required however where you are unsure select Back to revisi...

Страница 35: ...the phone number of the installed SIM card Cello time the time and date of the Cello 6S when the report was generated FEP the version of firmare currently installed on the Cello 6S Modem the version...

Страница 36: ...tails With the Cello 6 Wizard software displaying the Welcome page select Push data The software will now indicate all communication steps in the process of sending all the stored data in the Cello 6S...

Страница 37: ...ignal strength section of this manual with the Cello 6S being moved around until the strongest signal strength is obtained although be aware that it may not be physically possible to locate it in the...

Страница 38: ...structures In order to determine optimal Cello 6S performance a signal strength test should be perfomed as detailed in the Installation Commissioning Cello 6 Wizard Signal strength section of this ma...

Страница 39: ...ot les than 20mm Please contact Technolog where Cello 6S is required to fit in boundary boxes other than that shown Note Where the Cello 6S does not feature an external antenna connector i e it only h...

Страница 40: ...on of this manual the main body houses the circuit board internal antenna SIM card and replaceable battery pack Temporarily removing the lid allows access to the battery pack and SIM card As standard...

Страница 41: ...ttery pack is to be disposed of in a safe and environmentally sound manner Refer to the Precautions Lithium battery packs cells section of this document for further details Step 4 Before fitting the n...

Отзывы: