Supplementary - "Diagnostic"
- Ensure the "Cello 6 Wizard" software has already been setup as per the "Installation:
Commissioning - Cello 6 Wizard: Startup" section of this manual for details.
- With the "Cello 6 Wizard" software displaying the "Welcome" page select "Diagnostic".
- The software now interrogates the Cello 6S and produces the following report where:
"IMEI" = Unique indentifier of the internal modem module.
"Telephone Number" = the 'phone number of the installed SIM card.
"Cello time" = the time and date of the Cello 6S when the report was
generated.
"FEP" = the version of firmare currently installed on the Cello 6S.
"Modem" = the version of firmware currently installed on the internal
modem module.
"Base Stations" = The details of the provider of the cellular network the
Cello 6S is currently using.
"Error log" = modem module entire logged along with their identifiers
"Wizard Comms Error Log" = local communications status.
- After the report has been generated, if there is no further requirement to use the "Cello
6 Wizard" software with that particular Cello 6S, select "Exit" to terminate the software.
- Where further interrogation and / or setup of the particular Cello 6S is required, select
"Next". Refer to section "Step 5 - Signal strength testing" of "Installation:
Commissioning" onwads for further details.
Installation: Commissioning
- Cello 6 Wizard: Supplementary - Diagnostic