6.8. ERROR DETECTED BY BRAKE BOARD
When the brake board detects an error, it stops and interrupts the power supply to the brake
winding, and an error code identifying the fault condition is saved in the error history log. When
this error is received by the digital plan board, it halts the exercise and shows the “THE
EQUIPMENT IS BLOCKED” message on the display.
The errors logged by the brake board can also be viewed from the machine keyboard as described
in paragraph 9.3.4. “Errors log” or in paragraph 9.3.6.2 “Low Kit fault code”.
ERROR DETECTED BY
BRAKE BOARD
Check the error code
stored in memory
Error 1
Error 4
Error 8
Error 16 - 32
Error 2
Error 128
The following paragraphs describe the troubleshooting procedures for these cases.
6.8.1. E
RROR
1
ON BRAKE BOARD
This code indicates an overheating error: this condition occurs when the temperature detected by
the sensor on the circuit board exceeds 90°C.
Try switching the machine off for 1 hour. If it resumes working correctly, the machine probably
overheated as a result of intensive use. If, on the other hand, the error persists, it is necessary to
replace the brake board.
6.8.2. E
RROR
2
ON BRAKE BOARD
This code indicates an overcurrent error: this condition occurs when the current going to the
solenoid measured by the board exceed the max value
This error is caused by an HW problem on the brake board or a short circuit on the solenoid. To
solve the problem, it is necessary to replace the brake board or the solenoid.
6.8.3. E
RROR
4
ON BRAKE BOARD
This code indicates a low voltage error: this condition occurs when the +12 Vdc voltage drops
below 9.7 Vdc.