RECLINE EXCITE: Service & Maintenance Manual - rev. 1.3
6.1.1. A
UTOMATIC
T
EST
The tests grouped under this section conduct checks on the machine’s operation in a fully automatic
manner. After selecting the desired test using the
+
and – effort level keys, press
ENTER
to initiate
the test and then await the result. Press
ENTER
again to continue, and use the
CLEAR
key to
return to the higher menu level, holding it down for a few seconds. The various manual tests are
described below.
6.1.1.1. I2C Devices Test
The I2C Devices test checks the communication following the 32K and 256K memories and the
operation of the OwnZone receiver only for what concerns the data reception function, but not the
detection of the heart rate signal. The test can have two outcomes:
•
“Test Successful, press Enter to continue” :
Signifies that the transmission and reception of
data packets between the I2C devices and the digital plan board was completed successfully.
•
“OwnZone error, press Enter to continue” :
Signifies that the transmission and/or reception
of data packets between the OwnZone and the digital plan board was not completed
successfully.
•
“EEPROM Error, press Enter to continue”
: Signifies that the CPU board has communication
problems with the memories.
6.1.1.2. LED Test (not on 700E models)
The LED test checks the functioning of the display by lighting all the LEDs in the matrix. It also
tests the buzzer by changing the frequency to produce a variation in the tone of the sound.
There is no message displayed concerning the outcome of this test, which the user must therefore
check visually.
6.1.1.3. Serial Ports Test
The serial ports test checks the communications on the port for connecting to:
•
CSafe COM test;
•
Low Kit COM test;
•
TGS COM test.
Using the
+
and – effort level keys, select the desired test item and confirm by pressing
ENTER
.
The test can have two outcomes:
•
“Test Successful, press Enter to continue”:
This means that the test was completed
successfully, i.e. that the communications on the selected serial port are correct.
•
“COMx Error, press Enter to continue”:
This means that the outcome of the test was
negative: the message will specify COM1 in the case of the CSafe COM test, COM2 in the case
of communications with the low kit, or COM3 in the case of the TGS COM test.
6.1.1.4. Test
Result
This function is used for viewing the outcomes of the various tests:
•
EEPROM32K;
•
EEPROM256K;
Page 6.3