RECLINE EXCITE: Service & Maintenance Manual - rev. 1.3
Page 9.18
9.3.4.2. Reset
Errors
To clear the error history in both the low and high kit memory, scroll using the +/- keys until the
LED display shows:
RESET ERRORS ?
press
ENTER
to clear the error history logs, and return to the upper menu level by pressing
CLEAR
for a few seconds.
9.3.4.3. View
Errors
For every error generated by the machine, the error history log records the information in the table
below:
•
Counter
•
Error code
•
date (dd-mm-yyyy – hh:mm)
•
Current when the error occurred
•
Distance in km when the error occurred
The correspondence between error codes and descriptions is given in the table below:
Error
Code
Description
1
OVERHEATING:
this condition occurs when the temperature measured
by the sensor on the circuit board exceeds 90°C.
2
OVERCURRENT:
this condition occurs when the current going to the
solenoid measured by the board exceed the max value.
4
UNDERVOLTAGE:
this condition occurs when the +12 Vdc voltage
drops below 9.7 Vdc (only on the 500, 700 and 700E models).
8
OVERVOLTAGE:
this condition occurs when the +12 Vdc voltage goes
above 13.7 Vdc (only on the 500, 700 and 700E models).
16
WATCHDOG
: this condition occurs when the brake board SW crashes.
32
EPROM:
SW error on the brake board.
128
MACHINE NOT CALIBRATED:
this error condition occurs when the
calibration parameter stored in the brake board is incorrect.
Use the
+
speed key to advance to the next error, otherwise the message with the details of the
current error will continue to reappear.
9.3.5. S
TANDARD SETTINGS
This function simultaneously resets the brake interface board parameters to their default values, and
clears the operating data of the machine. To access this menu, when the LED display shows:
STANDARD SETTINGS ?
press
ENTER
, the following message appears:
CONFIRM ?