DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are:
Cooling: Indoor air temperature 27°C DB/19°C WB
Outdoor air temperature 35°C DB/24°C WB
Heating: Indoor air temperature 20°C DB
Outdoor air temperature 7°C DB/6°C WB
No. of indoor units. SYSTEM B
Power Source
220 – 240 V ~ 50 Hz
Cooling
Heating
Capacity
kW 5.1 6.3
BTU/h 17,400 21,500
Air circulation (High) m
3
/h 760
Moisture removal (High) Liters/h 2.2 —
Voltage rating V 230
Available voltage range V 198 to 264
Running amperes A 9.0 10.2
Power input W 2000 2100
Power factor % 97 90
C.O.P. W/W 2.55 3.0
Compressor locked rotor amperes A 54
Controls / Temperature control Microprocessor / I.C. thermostat
Control unit
Wireless remote control unit
Timer 24 hr ON / OFF
Fan speeds Indoor / Outdoor 3 and Auto / Auto (High, Low)
Airflow direction (Indoor)
Horizontal
Manual
Vertical
Auto
Air filter
Washable, Anti–Mold
Compressor
Rotary (Hermetic)
Refrigerant / Amount charged at shipment g R22 / 1750 (each system)
Refrigerant control Capillary tube
Power sound level
Indoor – Hi
dB-A 55
Outdoor – Hi dB-A 70
Refrigerant tubing connections Flare type
Max. allowable tubing length at shipment m 7.5
Refrigerant tube
Narrow tube
mm (in.)
6.35 (1/4)
diameter
Wide tube mm (in.) 12.7 (1/2)
Indoor Unit Outdoor Unit
Unit dimensions Height mm
Width mm see page 10 see page 11
Depth mm
package dimensions Height mm 276 1390
Width mm 1070 1141
Depth mm 363 418
Weight Net kg 8.0 128
Shipping kg 10.0 138
Shipping volume m
3
0.07 0.59
Dimensions & Weight
Features
Electrical Rating
Performance
Indoor Unit MCA180MR5TAA
Outdoor Unit GR360M3R5TAA
4
Содержание GR360M3R5TAA
Страница 15: ...Outdoor Unit GR360M3R5TAA 11...
Страница 24: ...8 2 Electric Wiring Diagrams Outdoor Unit GR360M3R5TAA Indoor Unit MCA90MR5TAA 20 Indoor Unit MCA180MR5TAA...
Страница 51: ...11 ARRANGEMENT OF ELECTRICAL COMPONENTS Terminal Plate Outdoor Unit GR360M3R5TAA 47 Electric Parts...
Страница 52: ...Outdoor Unit GR360M3R5TAA Parts Layout in Unit 48 Electronic Control Board Compressor A Compressor B...
Страница 53: ...Outdoor Unit GR360M3R5TAA 49 Solenoid valves lay out...