DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Part No. WSA –LTR
Controls Microprocessor
Control circuit fuse 250 V – 3.15 A
Remote Control Unit RC–2(WOA)
Type Cross–flow
Number ... Dia. and length mm 1 ... ø88 / L746
Fan motor model ... Number UF2–31A5PA -S... 1
No. of poles ... rpm (230 V, High) 2 ... 1305 / 1335
Nominal output W 30
Coil resistance (Ambient temp. 20°C)
Ω
WHT – BRN : 130.4
WHT – PNK : 169.8
Safety
Type Thermal protector
devices Operating temp.
Open °C 130 ± 8
Close Automatic reclosing
Run capacitor
µF 2.0
VAC 440
Type
Stepping motor
Model MP24GA2
Rating
DC 12 V
Coil resistance (Ambient temp. 25°C)
Ω
Each terminals (1-2, 1-3, 1-4, 1-5) : 400 ± 7%
Coil
Aluminum plate fin / Copper tube
Rows
2
Fin pitch mm 1.3
Face area m
2
0.250
Heat
Exch. Coil
Flap Motor
Fan & Fan Motor
Controller
PCB
Indoor Unit MCA180MR5TAA
7
Содержание GR360M3R5TAA
Страница 15: ...Outdoor Unit GR360M3R5TAA 11...
Страница 24: ...8 2 Electric Wiring Diagrams Outdoor Unit GR360M3R5TAA Indoor Unit MCA90MR5TAA 20 Indoor Unit MCA180MR5TAA...
Страница 51: ...11 ARRANGEMENT OF ELECTRICAL COMPONENTS Terminal Plate Outdoor Unit GR360M3R5TAA 47 Electric Parts...
Страница 52: ...Outdoor Unit GR360M3R5TAA Parts Layout in Unit 48 Electronic Control Board Compressor A Compressor B...
Страница 53: ...Outdoor Unit GR360M3R5TAA 49 Solenoid valves lay out...