AFTER USE 

When you have finished heating samples, remember that parts of the unit – the tubes, blocks and 
associated accessories – may be very hot. Take the precautions listed earlier. 

GUARANTEE 

The unit is guaranteed against any defect in material or workmanship for the period specified on 
the enclosed guarantee card. This period is from the date of purchase, and within this period all 
defective parts will be replaced free of charge provided that the defect is not the result of misuse, 
accident or negligence. Servicing under this guarantee should be obtained from the supplier. 

Notwithstanding  the  description  and  specification(s)  of  the  units  contained  in  the  Operator’s 
Manual, Techne hereby reserves the right to make such changes as it sees fit to the units or to 
any component of the units. 

This Manual has been prepared solely for the convenience of Techne customers and nothing in 
this  Instruction  Book  shall  be  taken  as  a  warranty,  condition  or  representation  concerning  the 
description, merchantability, fitness for purpose or otherwise of the units or components. 

OPERATOR MAINTENANCE 

NOTE: THAT THIS EQUIPMENT SHOULD ONLY BE DISMANTLED BY PROPERLY TRAINED 
PERSONNEL.  REMOVING  THE  SIDE, FRONT  OR  REAR  PANELS  EXPOSES  POTENTIALLY 
LETHAL  MAINS  VOLTAGES.  THERE  ARE  NO  OPERATOR  MAINTAINABLE  PARTS  WITHIN 
THE EQUIPMENT. 

In  the  unlikely  event  that  you  experience  any  problems  with  your  unit  which  cannot  easily  be 
remedied, you should contact your supplier and return the unit if necessary. Please include any 
details  of  the  fault  observed  and  remember  to  return  the  unit  in  its  original  packing.  Techne 
accept  no  responsibility  for  damage  to  units  which  are  not  properly  packed  for  shipping:  if  in 
doubt, contact your supplier. See the Decontamination Certificate supplied with your unit. 

1. Cleaning 

Before cleaning your unit ALWAYS disconnect it from the power supply and allow it to cool below 
50°C. 

Your unit can be cleaned by wiping with a damp soapy cloth. Care should be exercised to prevent 
water from running inside the unit. Do not use abrasive cleaners. 

2. Overtemperature cutout 

In the event of no heater power, check the mains plug and lead. Repeated operation of the cutout 
indicates a serious fault: you may need to return the unit to your supplier for repair. 

3. Fuses 

Your unit is protected by fuses. These should only be changed by suitably qualified personnel. If 
the fuses blow persistently, a serious fault is indicated and you may need to return the unit to your 
supplier for repair. 

 
 
 
 

Содержание IFB-201

Страница 1: ...IFB 201 OPERATOR S MANUAL...

Страница 2: ...ERS 10 INSTALLATION 10 NACH DEM GEBRAUCH 11 GARANTIE 11 WARTUNG DURCH DEN BEDIENER 11 INTRODUCCI N 13 AVISO 13 INSTALACI N 13 DESPU S DE SU USO 14 GARANT A 14 MANTENIMIENTO 14 INTRODUZIONE 16 ATTENZIO...

Страница 3: ...3 Spare Parts 31 Accessories 31 Circuit Diagrams 32...

Страница 4: ...protect the unit If a safety problem should be encountered the unit should be switched off and isolated from the mains electricity supply INSTALLATION This Techne Industrial Fluidised Bath IFB is desi...

Страница 5: ...Y PROPERLY TRAINED PERSONNEL REMOVING THE SIDE FRONT OR REAR PANELS EXPOSES POTENTIALLY LETHAL MAINS VOLTAGES THERE ARE NO OPERATOR MAINTAINABLE PARTS WITHIN THE EQUIPMENT In the unlikely event that y...

Страница 6: ...serait alors plus garantie Tous les appareils Techne sont con us pour r pondre aux normes de s curit internationales et sont dotes d un coupe circuit en cas d exc s de temp rature Sur certains mod les...

Страница 7: ...rantie condition ou repr sentation concernant la description commercialisation adaptation aux conditions d utilisation ou autre des appareils ou leurs composants ENTRETIEN UTILISATEUR IMPORTANT CET AP...

Страница 8: ...votre fournisseur pour r paration 3 Fusibles La protection de l appareil est assur e par un ou deux fusibles dont le remplacement ne peut tre effectu que par un personnel qualifi Si les fusibles saute...

Страница 9: ...die pers nliche Sicherheit des Anwenders beeintr chtigen Die Ger te von Techne entsprechen den internationalen Sicherheitsbestimmungen und sind mit einem automatischen bertemperaturabschalter ausgest...

Страница 10: ...lich dazu erstellt um Kunden die Handhabung der Techne Ger te zu erleichtern Nichts in dieser Gebrauchsanleitung darf als Garantie Bedingung oder Voraussetzung verstanden werden sei es die Beschreibun...

Страница 11: ...zur ck indem Sie den roten Knopf einmal bis zum Anschlag dr cken Wenn der bertemperaturabschalter wiederholt ausl st liegt ein gr erer Defekt vor Das Ger t mu zur Reparatur an Ihren Lieferanten einges...

Страница 12: ...rporados un sistema de desconexi n en caso de sobretemperatura En algunos modelos el sistema de desconexi n es variable lo que le permite elegir la temperatura seg n sus necesidades En otros el sistem...

Страница 13: ...garant a condici n o aseveraci n de la descripci n comerciabilidad o adecuaci n para cualquier fin espec fico de los aparatos o sus componentes MANTENIMIENTO ESTE APARATO DEBE SER DESMONTADO SOLO Y EX...

Страница 14: ...a desconexi n repetida indicar a una aver a grave puede que tenga que devolverle el aparato a su proveedor para su reparaci n 3 Fusibles Su aparato est protegido por uno o dos fusibles S lo deben camb...

Страница 15: ...di sicurezza e sono equipaggiate con un interruttore anti surriscaldamento Su alcuni modelli l interruttore regolabile e dovrebbe essere impostato secondo l utilizzo In tutti gli altri modelli l inte...

Страница 16: ...zione dei pannelli laterali frontali o posteriori pu esporre potenzialmente a voltaggi di corrente letali All interno dell apparecchio non ci sono parti manutenibili da parte dell utilizzatore Nell ev...

Страница 17: ...n of inflammable fumes above the bath and within the exhaust duct work must be kept below the lower explosive limit General Description The fluidised bath employs the principle of fluidisation of a ma...

Страница 18: ...sing air control valves Supplied as standard with this and all other options is an air pressure regulator and filter assembly During operation the correct fluidising air flow rate must be determined b...

Страница 19: ...80 minutes 20 C to 600 C 350 minutes Compressed air supply pressure 204 1030kPa 30 150psi Air consumption maximum 220 l min At 450 C 150 l min Nominal Heater Power 9kW Heater type 4 semi embedded heat...

Страница 20: ...nce between the top of the aluminium oxide and the top of the bath is 120mm when the bath is fully loaded Should the fluidised bath be stored for long periods of time under damp or humid conditions mo...

Страница 21: ...that the maximum fume concentration be less than 25 of the LEL f Measure the fume concentration in the working environment adjacent to the fluidised bath using suitable gas analysis equipment such as...

Страница 22: ...rticle size less than 0 005mm diameter which will not be retained by the cyclone it is recommended that a filtration system be fitted after the cyclone In applications where the materials being treate...

Страница 23: ...8L controller Al List Hy 1 Pid List Pb 20 ti 360 td 60 lcb Auto Hcb Auto OP List OpLo 0 OpHi 100 0 CycH 1 0 OntH 0 1 Accs List Full level Enter 5744 password Goto OPer select Full Enter SP List SSEL S...

Страница 24: ...luidised bath We recommend that protective clothing gloves aprons and visors etc be worn at all times when working with fluidised baths and that the installation and maintenance procedures outlined in...

Страница 25: ...d they should be allowed to cool in air and whilst still warm treated to prevent rusting It should be noted that some plastics and in particular paints contain fillers These fillers are usually inorga...

Страница 26: ...bath is self draining However it should be kept in good condition by inspection at two weekly intervals and by cleaning the bowls and washing or replacing the filter elements as necessary With excepti...

Страница 27: ...et In addition in water it produces water ions which even in neutral or alkaline solutions promote corrosion and rusting in steel witness for example the corrosive nature of sea water and calcium chlo...

Страница 28: ...le the medium may be thoroughly washed in several changes of clean water washed through a 70 mesh sieve drained dried and returned to the bath where drying is completed by fluidisation and heating at...

Страница 29: ...ally terminated within the control console see attached circuit diagrams for wiring details To inspect the heater elements remove the inner container from the outer wrapper The heater elements are of...

Страница 30: ...457 6500356 6500356 6500356 Fuse 2 Amp 6008321 6008321 6008321 6008321 6008321 Fuse 16 Amp N A N A 6008322 6008322 6008322 Fuse 35 Amp 6008324 6008324 N A N A N A Filter Kit Oil 6009247 6009247 600924...

Страница 31: ...32 Circuit Diagrams...

Страница 32: ...33...

Страница 33: ...34...

Страница 34: ...g the details below UK Office Keison Products P O Box 2124 Chelmsford Essex CM1 3UP England Tel 44 0 330 088 0560 Fax 44 0 1245 808399 Email sales keison co uk Please note Product designs and specific...

Отзывы: