8. Attach the light (as shown in Figure 16, Detail A) to the top of the user interface enclosure using the
socket screws provided.
9. If equipped with Batch Counter Kit 1424267-1, insert the batch counter kit into the appropriate
knockout opening until it snaps into place. The red reset button should be on the right-hand side.
10. Re-attach the connector from the machine wiring harness to the J1 connector on the pc board in the
interface assembly.
Socket Screws Provided
with Work Light Kit
Work Light Kit (Optional)
Batch Counter Kit (Optional)
Work Light Kit Knockout
Holes
User Interface Assembly
(Removed from Machine)
Red Reset Button
PC Board
J3 Connector
J1 Connector
User Interface Assembly
(As Viewed from the Bottom))