409-32034
Rev D
4 of 31
The specifications and requirements for the AMP 3K and AMP 5K Terminating Machines are as listed below:
Deflection
0.13 mm [.0046 in.] Maximum per 4,448 Newtons [1,000 lb] Crimp Force
Noise (Model 3k Series):
Less than 76 dBa Typical at operator position with standard mechanical feed applicator
Noise (Model 5k Series):
Less than 80 dBa Typical at operator position with standard mechanical feed applicator
Weight
68.86 Kilograms [143 lb]
Height
510 mm [20 in.] without reel supports
Electrical
100-240 Vac, 50/60 Hz, Single-Phase Current
Air
620-760 kPa [90-100 psi], 2.83 liters/sec (6 scfm) When required for use with air-feed applicators
Physical Environment:
Temperature: 4.4° to 40° C [40° to 104° F]
Relative Humidity: Less than 95% (non-condensing)
Transportation and Storage: Store in a clean, dry environment after coating all surfaces lightly with a rust
preventing oil.
Various TE applicators can be used in the AMP 3K and 5K terminating machines. Applicator instructions sheets
are packaged with each applicator. The applicator instruction sheets provide information on applicator
installation, care, and adjustment.
When reading this manual, pay particular attention to DANGER, CAUTION, and NOTE statements
DANGER
Denotes an imminent hazard that may result in moderate or severe injury.
CAUTION
Denotes a condition that may result in product or equipment damage.
NOTE
Highlights special or important information.
NOTE
Dimensions in this customer manual are in metric units [with U.S. customary units in brackets]. Figures are not drawn to scale.
2.
DESCRIPTION
The AMP 3K and AMP 5K Terminating Machines were designed to be used as stand-alone semi-automatic
bench units. They are assembled with metric hardware.
These machines accept a wide variety of miniature (mini) quick-change applicators (including the TE Ocean
Applicator), thus providing a great selection of terminals for many applications.
Older TE applicators use different feed cams depending on the machine stroke. Refer to Figure 2 for
changeover cams required to run 1 1/8-in. stroke cams (for AMP-O-LECTRIC* Model "K" terminating
machines) and 1 5/8-in. stroke cams (for Model "T" and Model "G" Terminating machines) in the machines.