114-106497
Rev 5
8
of 22
G. Wire Location
All conductors must be held firmly inside the wire barrel. No strands can be folded back over the wire
insulation. The wire insulation must be inside the insulation barrel but must not enter the wire barrel. The wire
insulation and conductors must be visible in the transition area between the wire barrel and insulation barrel.
See Figure 4.
H. Wire Brush
The conductors may extend beyond the wire barrel within the dimensions given in Figure 4.
I. Wire Barrel Seam
The wire barrel seam must be closed with no evidence of loose wire strands visible in the seam.
K. Twist and Roll
There should be no twist or roll of the wire barrel or mating portion of the crimped contact that would cause
overstress or impair usage. See Figure 4 for allowable limits.
NOTE
The effective crimp length depends on the crimping dies used and should not be measured for inspection purposes.
Wire Barrel Seam Closed with
No Visible or Loose Wire Strands
Wire Insulation and Conductors Both Visible in Transition
Area (Between Wire Barrel and Insulation Barrel)
No Wire Insulation Visible
in Insulation Barrel Seam
Insulation Barrel
Width (See Table)
Wire Brush (Conductors Extend
Beyond Wire Barrel) (See Table)
Rear Bellmouth
(See Table)
Contact Spring
is Not Deformed
Effective Crimp Length (Ref)
X
X
See Detail A
1.0 max. for Box Area
1.35 +/-0.05
Gap Should Not
Change After Crimp