114-106497
Rev 5
21
of 22
5.
VISUAL AID
The illustration below shows a typical application of this product. This illustration should be used by production
personnel to ensure a correctly applied product. Applications which do not appear correct should be inspected
using the information in the preceding pages of this specification and in the instructional material shipped with
the product or tooling.
Figure 16 (continued): Visual Aid
CUTOFF TAB AND BURR MUST
BE WITHIN LIMIT SPECIFIED
WIRE MUST NOT BE
NICKED, CUT, OR SCRAPED
THERE MUST BE NO WIRE
INSULATION VISIBLE IN
INSULATION BARREL SEAM
WIRE INSULATION AND
CONDUCTORS MUST BOTH BE
VISIBLE BETWEEN WIRE BARREL
AND INSULATION BARREL
WIRE BARREL SEAM MUST BE
CLOSED WITH NO VISIBLE OR
LOOSE WIRE STRANDS
THERE MUST BE NO
DAMAGE TO CONTACT
SPRING
REAR BELLMOUTH
MUST BE VISIBLE
TERMINATED CONTACTS MUST
BE INSERTED INTO THE
HOUSING IN PLACE
WIRE MUST NOT BE
DAMAGED IN ANY WAY
BOX HEIGHT MUST BE WITHIN
LIMIT SPECIFIED
CONTACT WIDTH MUST BE
WITHIN LIMIT SPECIFIED
GAP SHOULD NOT
CHANGE AFTER CRIMP
Содержание SGI 1.25
Страница 15: ...114 106497 Rev 5 15 of 22 Dual Row...