Problem
Corrective Action
Too many crimps are failing
that appear to be good.
Carefully inspect the crimp. Does it meet your quality criteria?
Some problems could be related to poorly maintained tooling. Ensure the tooling is in optimum condition.
Adjust the sensitivity of the analysis methods so that they are less sensitive. Experiment by changing the
sensitivity by about 0.5 at a time.
Is the headroom of the crimp above 35%?
Failed crimps are passing the
analysis.
Carefully inspect the crimp. Does it truly fail your quality criteria?
Adjust the sensitivity of the analysis methods so that they are more sensitive. Experiment by changing the
sensitivity by about 0.5 at a time.
Is the headroom of the crimp above 35%?
Terminator foot switch still
cycles the system when the
CQM failed a crimp and the
operator did not respond to
the error. (Depends on which
host is selected.)
Is the appropriate host system selected in the CQM Settings?
Is the interface cable connected to the DAQ module and the host terminator?
Is the interface cable damaged?
If the system is on a non-TE terminator, has it been properly connected?
The touch screen is not
responding AT ALL.
Plug in a USB mouse and navigate to the Touch Screen calibrate mode. Start the calibration with the
mouse, and then proceed with touching the screen. If touches are not recognized, the unit is not working
correctly. You can continue to operate the system with the USB mouse or return it for repair/replacement.
The touch screen is not
responding all of the time.
The calibration may be off. Go to the Touch Screen calibration and perform the calibration.
You may need to plug n a USB mouse to navigate to the Touch Screen calibration.