![TE Connectivity Crimp Quality Monitor II Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/te-connectivity/crimp-quality-monitor-ii/crimp-quality-monitor-ii_customers-manual_3955934039.webp)
409-10100
39 of 59
Rev C
Data Description:
CRIMP RESULT DATA
INSTANCE ID
- production run identifier.
CRIMP ID
- a unique identifier for the crimp in the production run.
OVERALL RESULT
- final result of all the analysis methods.
BATCH COUNT
- number of PASS crimps in the batch after the crimp.
TOTAL COUNT
- number of PASS crimps in the production run after the crimp.
TIME STAMP
- coded time stamp that represents the date and time of the crimp.
CQM NUMBER
- source CQM Unit number. (always 0)
IDLE FORCE
- idle force detected when the crimp occurred.
IDLE POSITION
- idle position detected when the crimp occurred.
PART NAME
- part name.
SEQUENCE POSITION
- position in the sequence. (always 1)
CRIMP MODE
- CQM unit mode when the crimp occurred.
CRIMP NUMBER
- number of crimps since powered on.
CALIBRATE RESULTS DATA (ONLY SHOWN FOR CALIBRATE CRIMPS)
GAIN VALUE
- gain value after the gain calibration crimp.
HAND MEASURED CRIMP HEIGHT
- entered measured crimp height during calibration.
CALIBRATE RESULT
- True or False.
CRIMP HEIGHT HISTORY DATA (ONLY SHOWN FOR PRODUCTION MODE CRIMPS)
CRIMP RESULT
- Pass or FailL from crimp height analysis
MEASURED CRIMP HEIGHT
- crimp height value from the crimp height analysis
UCL
- upper control limit
LCL
- lower control limi
NOMINAL CRIMP HEIGHT
- crimp height desired and set in the part.
CONTROL LIMIT
- value calculated or set in the part.
CALCULATE CONTROL LIMIT
- True or False.
CRIMP HEIGHT TOLERANCE
- allowable tolerance set in the part.
PEAK FORCE HISTORY DATA (PEAK FORCE ANALYSIS)
PEAK FORCE RESULT
- PASS or FAIL or LEARN from peak force analysis
FORCE
- peak force value from the peak force analysis
UCL
- upper control limit
LCL
- lower control limit
SENSITIVITY
- sensitivity setting for the peak force analysis