122
Fig.8-4: LIST Mode Sequence example
0.01sec
Trig Initated
INIT:IMM
WTG
(Wait Trigger)
Trigger Event
TDC
TRIG:DEL 0.02
STS
(Step Started)
DWELL
LIST:DWELL 0.05,0.06,0.03
STC
(Step Complited)
OPC
(Operation Complited)
OUTPUT
LIST:VOLT 5,10,0
VOLTAGE
0.02s
0.05s
0.06s
0.03s
LIST STEP AUTO
8.3 LIST Mode
Output change value in step determined by parameters in the LIST subsystem via input trigger.
Refer to section 7.12.8
Fig.8-3: Simplified Models of LIST Mode