111
LIST:VOLTage
Specifies the output voltage points in a list. The voltage points are given in the command parameters,
which are separated by commas.
SCPI Command Syntax
[SOURce]:LIST:VOLTage <NRf+> {,<NRf+>}
Default Suffix
V
Examples
LIST:VOLT 2.0,2.5,3.0 LIST:VOLT MAX,2.5,MIN
up to 12 parameters
Query Syntax
LIST:VOLT?
Returned Parameters
2.0,2.5,3.0
LIST:STORe
Saves data under specified numbers <1..4> of the last LIST typed (voltage or/and current, dwell
time, STEP parameter and counter).
SCPI Command Syntax
[SOURce]LIST:STORe <NR1>
Example
LIST:STORe 3
7.12.9 STATus Subsystem
Refer to Fig. 9-1 for more details.
STATus:OPERation:EVENt?
This query returns the value of the Event register. This is a read-only register that receives data from
the Condition register according to Enable register setting. Reading the Event register clears it.
SCPI Command Syntax
STATus:OPERation:EVENt?
GEN Command Syntax
SEVE?
Parameters
None
Returned Parameters
<NR1> (Register Value) decimal
Examples
STAT:OPER:EVEN?
STATus:OPERation:CONDition?
Returns the value of the Condition register, which is a read-only register that holds the real-time
(unlatched) operational status of the power supply.
SCPI Command Syntax
STATus:OPERation:CONDition?
GEN Command Syntax
STAT?
Parameters
None
Returned Parameters
<NR1> (Register Value) decimal
Examples
STAT:OPER:COND?
Содержание Z160-1.3
Страница 5: ...This page intentionally left blank...
Страница 27: ...26 Pages 26 33 are reserved for Z600 800W...
Страница 28: ...27 Pages 26 33 are reserved for Z600 800W...
Страница 29: ...34 2 6 Z200W 400W 600W 800W Outline Drawing...
Страница 30: ...35 2 7 Z200W 400W 600W 800W Optional IEEE Isolated Analog Interface Outline Drawing...
Страница 31: ...36 This Page intentionally left blank...
Страница 137: ...NOTES...
Страница 138: ...NOTES...
Страница 139: ...NOTES...