Figure 5-6: Daisy-Chain Connection
5.17
FRONT PANEL LOCKING
The front panel controls can be locked to protect from accidental power supply parameter change. Press and
hold the
PREView
button to have the VOLTAGE meter cycle between “Locked Front panel” (
LFP
) and
“Unlocked Front Panel” (
UFP
). Releasing the
PREV
iew button while one of the modes is displayed, selects that
operating mode.
Unlocked Front Panel
5.17.1
In this mode, the front panel controls are Enabled so that the user is able to program and monitor the power
supply parameters.
Locked Front Panel
5.17.2
In this mode the following front panel controls are
Disabled
:
VOLTAGE
and
CURRENT
encoders
FOLD
button
OUT
button
The power supply will not respond to attempts to use these controls and the
VOLTAGE
meter will display
“
LFP
”
to indicate that the front panel is locked.
The
OVP/ UVL
button is active to
PREV
iew the
OVP
and
UVL
settings.
Use the
PREV
iew button to display the Output voltage and Output current limit settings or to unlock the front
panel.