83-517-000 Rev.
A
38
4.3
REAR PANEL
See Figure 4-2 to review the connections and controls located on the power supply rear panel. Refer to Table 4-
2 for explanations about the rear panel connections and controls.
Figure 4-2: Rear Panel Connections and Controls
Table 4-2: Rear Panel Connections and Controls
Number
Item
Description
Section
1
AC input connector
Header with a screw plug connector (Phoenix Contact
P/N PC6-16/4-GF-10,16)
3.7
2
DC output
Bus-bars for 8V to 100V models.
Wire clamp connector for 150V to 600V models (shown
in Figure 4-2).
3.9.6
3
Remote-In connector
RJ-45 type connector, used for connecting power
supplies to RS-232 or RS-485 port of computer for
remote control purposes. When using several power
supplies in a power system, the first unit Remote-In is
connected to the computer and the remaining units are
daisy-chained, Remote-In to Remote-Out.
7.3
7.4
4
Remote Out connector
RJ-45 type connector, used for daisy-chaining power
supplies to form a serial communication bus.
7.3
7.4
5
Programming and
Monitoring connector
Connector for Remote Analog interface. Includes Output
voltage and Output current limit programming and
monitoring signals, Shut-off (
SO
) control (electrical
signal), Enable/Disable control (dry-contact), Power
Supply OK (
PS_OK
) signal and operation mode (
CV/CC
)
signal.
4.5
6
SW1 Setup switch
Nine position DIP-switch for selecting Remote
Programming and Monitoring modes for Output voltage,
Output current and other control functions.
4.4
4.4.1
4.4.2
7
Remote Sense
connector
Connector for making remote sensing connections to the
load for regulation of the load voltage and compensation
of load wire voltage drop.
3.8.2
3.10.2
3.10.3
8
Blank Sub-plate
Blank sub-plate for standard units (shown).
LAN
connector for LAN Interface option,
IEEE
connector for
IEEE option,
USB
for USB Interface option and
Isolated
Analog
connector for Isolated Analog Interface option.
9
Auxiliary Power
Auxiliary power supply
4.3.1
10
Ground Stud
M4 stud and hardware for chassis ground connection.