32
Total Control Systems
www.tcsmeters.com
3) ACTIVATE PRODUCT
Activate Product allows you to activate a product for a specific Shift. When liquid in your
tank changes, you can change the product and calibration to match.
-
To Activate a product, highlight the product and press ENTER.
4) DEACTIVATE PRODUCT
Deactivate Product allows you to deactivate an active Shift product. When liquid in
your tank changes, you can also change the product.
5) PRODUCT PARAMETERS
Product Timing allows auxiliary device settings to be changed to suite the needs of the
application. Currently set up for Product Density, Preset Valve, Air Eliminator Hold, Startup
Volume and Hose Volume. Also allows to preview and print the product parameters.
Product Timing is product specific, adjusting the actuation or closure type.
PRODUCT DENSITY
Select the Product to enter the Terminal density value. This will manually calculate the
value of your Mass delivery.
PRESET TIMING
Preset Timing adjusts the valve closure type for preset or security valves. Highlight the
Preset Timing function desired and press ENTER. This will be chosen as your default setting for
the specific Product.
Full-Auto
Full Automatic tune preset shutoff for Solenoid S1 (fast) and S2 (slow) flow valves. Great for
presets with varying system pressures.
NOTE: Solenoid S1 (fast) flow closure is 20% of average flow rate.
Semi-Auto
Semi-Automatic tuned preset shutoff for Solenoid S2 (slow) flow valve. Highlight Semi Auto
and press ENTER. Input Solenoid S1 (fast) flow valve closure and press ENTER.
Next Fix
Next Fix is an automatic tune shutoff, however it will allow the preset to overrun batch
amount. Designed to automatically correct the shutoff on the next preset delivery. Highlight
Next Fix and press ENTER. Input Solenoid S1 (fast) flow valve closure and press ENTER.
Static
Static settings for the Solenoid S1 (fast) and S2 (slow) flow valves. There is no automatic
correction for zero point shutoff. Highlight Static and press ENTER. Input Solenoid S1
(fast) flow valve closure and Solenoid S2 (slow) flow valve Values and press ENTER.
NOTE: for Solenoid S2 (slow) flow valve timing, run a separate preset batch with the S2 at
Zero. What volume is over run and read on the screen after the shutoff should be input into the
S2 (slow) valve timing.
AIR ELIMINATOR HOLD
When the TCS 3000 senses air, the Solenoid S1 and S2 preset relays will
de-energize for closure and energize the Auxiliary Relay open for the exhaust port to remove air
from the system. Highlight Air Eliminator Hold and press Enter. The HOLD (s) is the adjustable
setting for the Auxiliary Relay closure in Seconds. Input value in Seconds and press ENTER.
STARTUP VOLUME
Is a soft-start mechanism at the beginning of a delivery through which the S1 fast flow
valve will stay closed for scalable time (Seconds). Startup Volume will work with either the
Valve Type 1101 or 1001 valve actuation.
PREVIEW PROD PARAMS
Preview the product parameters by pressing ENTER, then scroll through each
page to see what values are selected for each parameter.
PRINT PRODUCT PARAMS
Print the product parameters by pressing ENTER if a printer is enabled. All
values will be printed for each parameter for review.