DR
AF
T
ON
X
X
OFF
X
WiFi Access Point mode.
ON
X
X
X
ON
WiFi Full. The limit of how many WiFI devices /
throttles can be connected to the CS-105 is reached.
ON
ON
X
X
X
Track power enabled.
ON
OFF
X
X
X
Track power disabled (E-Off).
ON
FB
X
X
X
Short circuit detected.
ON
SB
X
X
X
Thermal overload detected.
ON
X
ON
X
X
CAN bus connected.
ON
X
OFF
X
X
CAN bus disconnected.
ON
X
FB
X
X
LCC activity (TX).
ON
ON
ON
ON
ON
Configuration mode, will exit this mode after 30
seconds of inactivity.
ON
one to five synchronous blinks
Configuration mode, waiting to commit a configuration
change. The change will be committed after 12
seconds.
ON
FB
X
X
FB
Firmware upgrade mode.
LED1 & LED4 alternating blinks
10.1.1 Troubleshooting Steps
Problem: There is no power on the track output (Mainline)
Check the Power LED
● The Track LED is off
Check the Power Supply. If the power supply is unplugged, plug it in and check the Power
LED. If the Power LED remains off, make sure that the power supply > wall cord is securely
installed and is plugged into a live socket. If the socket is not live, check for tripped circuit
breakers, etc.
The power supply from TCS should include an on-board Blue LED which indicates that the
power supply is operational. If this Blue LED on the power supply is not lit, the power supply
is not receiving input power, or is otherwise not functioning.
●
The Track LED is on
System is receiving incoming power; Continue to the next steps.
Check the Track LED.
● The Track LED is off.
The track power has been turned off. You will also see a “POWER OFF” label on TCS throttles.
© 2022 Train Control Systems
Page 42 of 49