User Manual of Solar Intelligent Energy System (SIES)
TBB Power Confidential Page
47
of
66
Table 31 Information area of Energy Consumption
Alphabet
Items
Description
A
Load condition
Displays the output voltage of Energier Pro, output power in
KW, output in KVA, and percentage of Inverter load in turn.
B
Energy flow bar
Indicates the Energy Flow from Grid or Generator for powering
the load
C
Programmable AC
outputs
Shows the status of two programmable AC output, ON or OFF
D
Energy Consumption
Displays the daily energy consumption in KWh and total energy
consumption since installation in KWh
E
Energy flow bar
Indicates that the battery is being discharged to power the
loads
6.2.4 AC Sources
Figure 36 Information area of AC sources
Table 32Information area of AC sources
Alphabet
Items
Description
A
Energy flow bar
Indicates that either Grid or Generator is powering the loads
B
Grid
The icon is light on when grid is available
C
AC source status
Displays the voltage and frequency of AC inputs in turn
D
Generator
The icon is light on when generator is available. TAI (Twin
AC Inputs device) should be exist.
E
Energy
Consumption
Displays the daily energy consumption of AC sources in
KWh and total energy consumption of AC sources since
installation in KWh
F
Energy flow bar
Indicates that either grid or generator is charging the battery