User Manual of Solar Intelligent Energy System (SIES)
TBB Power Confidential Page
48
of
66
6.2.5 Battery Status
Figure 37 Information area of Battery Status
Table 33 Information area of Battery Status
Alphabet
Items
Description
A
Temperature Icon
Icon of temperature
B
Energy Flow bar
Indicates that PV array is charging battery
C
Energy Flow bar
Indicates that battery is being discharged to power the loads
D
Battery AH
Battery capacity
E
Energy Flow bar
Indicates that AC source is charging battery, either Grid or Generator.
F
Battery type
Battery type
G
Battery energy
Remaining energy within the battery in Ah
H
Time to go
How many minutes will the battery continually power the current loads
I
Battery voltage
Voltage level of battery
J
Battery SoC
Battery state of charge in %
K
Fault code and EQ
Fault code and status of Equalization Charging in case of trigger on
L
Temperature
Displays the ambient temperature and battery temperature in turn
6.3 System Configuration
The following parameters of SIES system can be set through three ways: 1) Cyber; 2) SmartPhone
App, 3) Web-based remote monitoring platform named TBB Energy Management Solution (TEMS)
1) System settings:
Data, Time
2) AC input settings:
AC Source, AC input range, AEA function
3) Battery and AC charger settings: Disable AC Charger, Battery type, battery capacity