![Taylor H60 Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/taylor/h60/h60_operators-manual_822765033.webp)
29
Model H60
Operating Procedures
010917
Step 2
Remove the spinner blade from spinner housing.
Remove the spinner bearing from the draw valve and
the spinner housing from the freezer door spout.
Disconnect syrup lines from fittings on front panel.
Take these parts to the sink for further cleaning and
sanitizing.
Step 3
Remove the rear drip pan, front drip tray, and splash
shield and take to the sink for further cleaning.
Rinse these parts in cool, clean water. Prepare a small
amount of an approved cleaning solution and brush
clean parts.
Step 4
Place the spinner housing, spinner blade, spinner
bearing, front drip tray, and splash shield on a clean,
dry surface to air- dry overnight or until the heating
cycle is complete.
Step 5
Prepare a small amount of an approved 100 PPM san-
itizing solution. USE WARM WATER AND FOLLOW
THE MANUFACTURER’S SPECIFICATIONS. Sanit-
ize the air tube assembly, agitator, hopper cover, and
rear drip pan.
Important: Install the agitator back onto the
agitator housing.
Note:
Press the <- - key to stop the agitator motion
for 10 seconds.
Step 6
Install the air tube assembly. Lift and turn the inner air
tube of the assembled air tubes so the pin rests on top
of the outer air tube. This will close the hole in the
assembled air tubes, preventing mix in the hopper
from entering the freezing cylinder during the heating
and standby process.
Figure 31
Step 7
Replace the hopper cover and install the rear drip pan.
Step 8
Return to the freezer with a small amount of cleaning
solution. Dip the end brush into the cleaning solution
and brush clean the door spout and bottom of the draw
valve.
Note:
To assure sanitary conditions are maintained,
brush each item for a total of 60 seconds, repeatedly
dipping the brush in cleaning solution.
Rinse a single service towel in cleaning solution and
wipe down the freezer door and area around the
bottom of the freezer door.
Note:
Once the heating cycle has started it cannot be
interrupted. The heating cycle will take a maximum of
3 hours to complete.
DO NOT draw product or attempt to
disassemble the unit during the HEAT cycle.
The
product is hot and under extreme pressure.
When the heating cycle is complete, the control will
return to the STANDBY mode.
There are three phases of the heat cycle; Heating,
Holding and Cooling. Each phase has a time limit. If
any 1 of the 3 phases fails to reach the proper
temperatures within the time limit, the cycle will
automatically abort and return to the STANDBY mode.
The LCD will display the message “HEAT TREAT
CYCLE FAILURE - FREEZER LOCKED - PRESS
SEL KEY”. The product may not be safe to serve. The
freezer will be locked out of the AUTO mode. Discard
product and brush clean machine.