150206
Press the MENU/SEL key to view the SERVINGS
COUNTER screen. The SERVINGS COUNTER
screen indicates the number of times the draw switch
has closed (number of draws) since the last brush
cleaning or since the last serving counter reset. A
maximum of 32,767 draws can be recorded; an
additional draw will cause the counter to restart at zero.
Pressing the MENU/SEL key will return the display to
the Operator Menu.
SERVINGS COUNTER
DRAWS
12
SEL
Draws are counted during the AUTO mode of
operation only.
Screen “H” is HEAT CYCLE DATA. The information
from the previous heat treatment cycles can be
obtained through this screen. The most recent heat
treatment cycle data will be shown first; press the plus
key to scroll through the remaining heat cycle displays.
If a heat treatment cycle failure should occur, a two
character message will appear on the second line of
the screen. Press the MENU/SEL key once to return
to the OPERATOR MENU.
00:00
00:00
00:00
HEAT
OVER
COOL
RC
00:00
00:00
00:00
TEMP AT END
0.0
1
Listed below are the variable messages which could
appear:
HT
Failure in the heating phase.
CL
Failure in the cooling phase.
TT
Failure in meeting total heat treatment cycle
time requirement.
MO Mix out condition.
OP Operator interruption.
PF
Power failure. (If a power failure occurs, but
the heat treatment cycle does not fail, an
asterisk (*) will appear on the 3rd line of the
display.)
BO Beater overload.
HO High pressure cut- out.
TH
Failed thermistor probe.
PS
Power switch placed in the OFF position.
ML Mix Low Condition.
14
14 Day Timeout Occurred.
RC Heat Cycle Record Cleared.
Pressing the CALIBRATE key on any HEAT CYCLE
DATA screen will cause the extended data screen to
be displayed. This screen shows the hopper, barrel,
and glycol temperatures, and the amount of time the
freezer spent in the phase of the heat cycle when the
heat cycle completed, or was terminated.
HOPPER
BARREL
GLYCOL
151.0
134.5
178.0
PHASE TIME: 1:20
1
Screen “I” is the LOCKOUT HISTORY. This screen
displays a history of the last 40 hard locks, soft locks,
and brush clean dates. Page numbers are indicated in
the upper right hand corner. Page 1 always contains
the most recent failure. Press the PUMP/+++ key to
cycle through the pages.
The second line of the screen displays the date and
time a failure occurs. The third line indicates the
reason for a failure, or will indicate a successful brush
cleaning has occurred. Some failures occur for
multiple reasons. When this occurs, a page will be
generated for each reason. Press the MENU/SEL key
once to return to the Operator Menu.
LOCKOUT HISTORY
1
11/21/01
02:08
SOFTLOCK ABORT
+++
- - -
SEL
Screen “J” is FAULT HISTORY. It will display up to 40
faults that have occurred. The most recent fault is
displayed on screen 1. The date, time, and fault
description is displayed on each screen.
FAULT HISTORY
1
00/00/00
00:00
REASON
+++
- - -
SEL
Screen “K” is the SERVICE MENU. This screen can
only be accessed by a service technician.