![Taylor H60 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/taylor/h60/h60_operators-manual_822765017.webp)
13
Model H60
Important: To the Operator
Power Switch
When placed in the ON position, the power switch
allows control panel operation. The power switch is
located on the left side of the control channel.
Liquid Crystal Display
The Liquid Crystal Display (LCD) is located on the front
control panel. The LCD is used to show the current
mode of operation, and whether or not there is
sufficient mix.
LCD Indicator - MIX LOW
The “MIX LOW” indicator flashes to indicate that there
is a low supply of mix. The mix hopper should be filled
as soon as possible.
LCD Indicator - MIX OUT
The MIX OUT light will illuminate, indicating that the
mix hopper has an insufficient supply of mix to operate
the freezer. The MIX OUT indicator will flash. At this
time, the freezer will go into the STANDBY mode of
operation. To return the freezer to the AUTO mode, fill
the hopper with mix and press the AUTO key. The
freezer will automatically begin operation.
Consistency Control
The viscosity (thickness) of the shake is controlled by
a sensing device called the consistency control. The
consistency control knob is located to the lower right
of the control channel. To achieve a thicker shake, turn
the knob clockwise and counterclockwise to achieve a
thinner shake consistency.
Allow the refrigeration system to cycle on and off 2 or
3 times before an accurate consistency can be
evaluated.
Flavor Selector Keypad
Four shake flavors are offered from the Model H60
freezer: chocolate, strawberry, vanilla (unflavored
product), and an optional flavor. Press the desired
shake flavor key and open the draw valve. Product and
syrup will automatically blend to produce the chosen
flavor.
RINSE
After the shake is drawn, press the RINSE key to rinse
excess syrup and mix from the spinner housing.
Reset Mechanism
The reset button is located under the right side panel.
The reset mechanism protects the beater motor from
an overload condition. If an overload occurs, the reset
mechanism will trip. To properly reset the freezer,
press the reset button firmly and clear the tone per
instructions in “Clearing Fault Tones” on page 17.
If the reset mechanism trips again, contact your
authorized Taylor Distributor to resolve the problem.
Warning: Do not use metal objects to
press the reset button. Failure to comply may
result in severe personal injury or death.