18
Model H60
Important: To the Operator
081111
Screen “C” is SET CLOCK. This screen will display the
current date and time. The date and time may only be
changed after the freezer has been manually brush
cleaned but before it has been placed in the AUTO
mode. Move the cursor under the number you wish to
change. Press the plus key to increase the number;
press the minus key to decrease the number. When
the desired time and date appears, press the
MENU/SEL key once to return to the OPERATOR
MENU.
SET CLOCK
10:21 AM
11/07/2001
- -
<- - - - - - >
+++
- - -
SEL
If an illegal date is entered, the following screen will
appear. The correct date must be entered before
leaving this display.
SET CLOCK
10:34 AM
02/30/2001
- -
INVALID DATE
<- - - - - - >
+++
- - -
SEL
Screen “D” is SET RINSE TIME. This screen is used
to set the amount of time needed to rinse the spinner
housing of syrup after a shake has been drawn. Press
the plus key to increase the number; press the minus
key to decrease the number. When the desired time
appears, press the MENU/SEL key once to return to
the OPERATOR MENU.
SET RINSE TIME
TIME: 3.0 SEC
+ + +
- - -
SEL
Screen “E” is SYSTEM INFORMATION. The first
screen will indicate the software version used in the
unit.
SOFTWARE VERSION
H60 Control UVC2
Version 2.03
SEL
Press the MENU/SEL key to view the second screen
of the SYSTEM INFORMATION display. This screen
will indicate the version number and number of
language strings.
Language
V1.14r00
English
539
SEL
Press the MENU/SEL key to view the third screen of
the SYSTEM INFORMATION display. This screen will
indicate the Bill of Material number and serial number
for the unit. Press the MENU/SEL key once to return
to the Operator Menu.
B.O.M.
0H6027E710
S/N
K0000000
SEL
Screen “F” is AUTO HEAT TIME. This screen is used
to set the time of day in which the heat treatment cycle
will start. Move the cursor under the number you wish
to change. Press the plus key to increase the number;
press the minus key to decrease the number. When
the desired time appears, press the MENU/SEL key
once to return to the OPERATOR MENU.
AUTO HEAT TIME
TIME: 12:00 AM
- -
<- - - - - - >
+++
- - -
SEL
Screen “G” is CURRENT CONDITIONS. This screen
gives the viscosity of the product and the hopper and
barrel temperatures. The last line of the display is the
compressor countdown safety timer. The safety timer
prevents the compressor from running more than 11
minutes (other than during the cooling phase of the
heat treatment cycle).
VISC
HOPPER
BARREL
0
38.5
28.5
TIME C
11:00
11:00