27
Model H60
Operating Procedures
150626
Step 6
With a pail beneath the dispensing spout, open and
close the draw valve six times. Draw off the remaining
sanitizing solution.
Figure 24
Step 7
Once the sanitizer stops flowing from the dispensing
spout, close the draw valve and press the WASH key,
cancelling the beater motor operation.
IMPORTANT!
The unit must NOT be placed in
“AUTO” until all sanitizing solution has been removed
from the freezing cylinder and proper priming
procedures have been completed. Failure to follow this
instruction may result in damage to the freezing
cylinder.
Note: Be sure your hands are clean and sanitized
before continuing these instructions.
Step 8
Lubricate the o- rings on the inner and outer air tubes.
Place the inner air tube inside the outer air tube and lay
in bottom of mix hopper.
Figure 25
Step 9
Stand the assembled air tubes in the corner of the mix
hopper and place the agitator on the agitator housing.
Figure 26
Note:
If the agitator stops turning during normal
operation, remove the agitator from the agitator
housing and brush clean these parts with sanitizing
solution. Install the agitator back onto the agitator
housing.
Be sure your hands are sanitized when
performing this step.
Priming
Step 1
Place a pail beneath the dispensing spout, and open
the draw valve. Pour two gallons (7.6 liters) of FRESH
mix into the mix hopper and allow it to flow into the
freezing cylinder. This will force out any remaining
sanitizing solution.
When full strength mix is flowing from the dispensing
spout, close the draw valve.
Figure 27