FLASHING OR
COURTESY LIGHT
12 V dc OUTPUT for FLASHING LIGHT, max. 20 W
+ Terminal 11, - terminal 14.
With jumper J1 you can select the COURTESY LIGHT function.
GATE OPEN
INDICATOR LIGHT
12 V dc INDICATOR LIGHT OUTPUT, max. 15 W
It is on from the beginning of the opening manoeuvre up until the gate is completely closed.
+ Terminal 12, - terminal 14.
ELECTRIC LOCK
12 V dc ELECTRIC LOCK OUTPUT, max. 15 W
It is active for 1 second before and 2-6 seconds after the gate starts opening, delayed in closing
(M1).
+ Terminal 13, - terminal 14.
CONNECTIONS TO TERMINAL BOARD COMMANDS SIDE
PEDESTRIAN
PEDESTRIAN push button input (Normally Open contact); its function is identical to that of the
PUSH BUTTON
OPEN/CLOSE
Terminal 15, 17=Common
OPEN/CLOSE
PUSH BUTTON
OPEN/CLOSE PUSH BUTTON (or STEP-BY-STEP). The function of this input depends on dip
switches 3 and 4 (COMMAND CARD). It is possible, via DS3, to exclude reversal of direction
during opening, or the OPEN/STOP/ CLOSE/STOP function with DS4.
Normally open contact.
Terminal 16, 17=Common
STOP PUSH BUTTON
Activation of this push button causes the gate to stop whatever manoeuvre it was doing. It will
only start again by pressing the OPEN/CLOSE push button.
Normally closed contact.
Terminal 18, 17=Common
PHOTO-DEVICE
SAFETY INPUT for PHOTO-DEVICES, MOBILE EDGES etc. For operating modes please see
the COMMAND CARD instructions.
Normally closed contact.
Terminal 19, 17=Common
FIXED EDGE
FIXED EDGE INPUT. During the opening phase the coming into play of the fixed edge will
cause reclosing for about 2 seconds. In the closing phase it will cause reopening for about 2
seconds.
Normally closed contact.
Terminal 20, 17=Common
CONNECTIONS TO TERMINAL BOARD
2ND RECEIVER
CHANNEL
SECOND RECEIVER CHANNEL CONTACT OUTPUT.
Using a two-channel receiver it is possible to control, for instance: lighting systems, another
unit, etc.
1 2
See receiver instructions for technical contact specifications.
CONNECTIONS TO TERMINAL BOARD ENCODER
MOTOR 1 ENCODER
MOTOR M1 ENCODER INPUT.
Terminal n° 21,+ / brown
Terminal n° 22, - / bleu
Terminal n° 23 pulse input / white
MOTOR 2 ENCODER
MOTOR M2 ENCODER INPUT.
(only for MEC20 vers.)
Terminal n° 21,+ / brown
Terminal n° 22 - / bleu
Terminal n° 24 pulse input / white
CONNECTIONS TO TERMINAL BOARD
RECEIVER AERIAL
RECEIVER AERIAL INPUT.
1 2
Connect SHIELD to terminal n° 1, WIRE to terminal n° 2. If an adequate earthing system is not
available we suggest you do not connect the aerial shield (terminal n° 1).