7.
MAINTENANCE
Tapflo LPX series
51
Tab. 12:
Radial clearances
Pump model
Radial clearance (mm)
Max.
Min.
25-1
25-2
40-1
0.18
0.11
40-2
50-1
0.27
0.15
50-2
80-1
0.39
0.23
100-1
0.42
0.25
1.
With the rotors synchronized, measure the radial clearance of each lobe (Figure 64,
item A) and verify that the clearance falls within the range shown in Table 12.
2.
Check clearance at all six points in the body as shown. See Figure 64, item B.
7.8.12.
Gear cover installation
Fig. 65:
Gear Cover Installation
Tab. 13:
Oil volume
Pump model
Oil volume (ml)
Max.
Min.
25-1
25-2
40-1
40-2
50-1
100
170
50-2
80-1
325
490
100-1
625
1125