Administrator Settings
169
4.5.2 Outputs
Audio out 1 - 3
Audio out 1 is intended for connection to TANDBERG Digital Natural Audio Module, televisions or
audio amplifiers.
Audio out 2 is intended for connection to audio recording equipment or to a telephone add-on
hybrid. The signal is a mix of audio from both the far end and local end (not from Audio in 5).
Audio out 3 is intended for connection to a VCR or other recording equipment. The signal is a mix
of audio from far end and local end (not from Audio in 6).
Note that audio out 2 or audio out 3 never should be connected to a loudspeaker placed in the
same room as the microphones connected to the system. This will cause “howling” and possible
damage to the speaker system. If an output is Off, no audio will be sent to that output.
Out 1 Mode
If Out 1 Mode is set to Auto, the system will select analog or digital (SPDIF) mode dependent on
the detected Audio Module. If a TANDBERG Digital NAM is detected, SPDIF mode will be
selected, otherwise analog mode will be selected.
Setting the Out 1 Mode to either Analog or SPDIF will override the auto-detected mode.
See
Stereo Settings
for more information.
Audio Module
Select Audio Module according to the type of Audio Module installed if this is not automatically
detected. The Audio Module setting is only available if the audio module of the system is
unidentified.
Level Settings
Adjust the audio output levels according to the parameters of the external audio equipment
connected. These levels should only be adjusted when installing new audio equipment. The
default settings are correct for the TANDBERG Digital Natural Audio module and for most
consumer electronics devices (televisions, VCRs, etc.). The volume keys on the remote control
adjust the level of output 1 (the speaker output). The volume control has no effect on other
outputs.
Содержание 700 MXP
Страница 14: ......
Страница 27: ...Installation 13 Figure 6 Figure 7 ...
Страница 55: ...General Use 41 ...
Страница 140: ...TANDBERG 7000 MXP 126 PC Presentation shown in Wide stretched mode ...
Страница 196: ...TANDBERG 7000 MXP 182 Voice Switched mode ...
Страница 198: ...TANDBERG 7000 MXP 184 4 7 Security Security contains the settings Encryption Encryption Mode Passwords ...
Страница 243: ...Peripheral Equipment 229 All signals are electrically according to RS232 Cable length max 5 meter X21 ...
Страница 249: ...Peripheral Equipment 235 ...
Страница 255: ...Peripheral Equipment 241 ...
Страница 283: ...Glossary 269 Dimensions Front view Side view Rear view Underside view ...
Страница 290: ...TANDBERG 7000 MXP 276 Figure 1 3 Enter the Release key in the Release Key field and press the Install Software button ...
Страница 295: ...Glossary 281 6 16 Appendix 16 Declaration of Conformity ...
Страница 296: ...TANDBERG 7000 MXP 282 6 17 Appendix 17 Dimensions ...