30450712 MPEG-4 Hi-Resolution DVR
25
Loss
TIP – Highlight means display the message for alarm output in
the screen
Monitor lock – Highlight means you can not see live monitoring
on the monitor but DVR is still recording over internet, only the
administrator can see the picture
13.
Schedule
– Select type ( General, Motion detection and alarm
recording) and the corresponding channel in channel then set
recording schedule; user can set 2 period every day in a week
separately
g
means the recording enabled
Time1 and Time2 express the timed recording period of the current
channel. Time2 should be after the ending time of time1 the setting
range is 00:00 ~ 24:00
Note : If you need record all day long set Time1 as 00:00~24:00
on while set Time2 as off
14.
RS232
– Add and choose the corresponding protocol to realize
functions the available protocols are as below :
Debug – used when upgrading and debugging the program
through mini terminal
DHKB - used when controlling DVR by keyboard (
3045079
)
DATEBIT – From 1 to 8
STOPBIT – has three options : 1,1.5,2 bit
VERIFY – including odd and even parity
15.
Network
– IP Address is set by using
pq
or input the exact
numbers to change the IP address ( IP Address can only be set in
this term) Then set the relate SUBNETMASK and GATEWAY
HTTP – default 80
TCP – default 377777 and can be change if need
PROTOCOL – choose the corresponding network transmission
protocols, such as TCP/IP and Multicast (Multicast is extendable)
16
. Alarm
Alarm in – select the related channel
Type –
has No (normal open)/NC (normal close) voltage output modes
REC Channel – select and display the recording channel when there
is alarm input ( can choose more than on channel ). IF the camera
number is selected, recording would be started for that camera
automatically when there is alarm input
Alarm out – choose alarm output port when there is an alarm
input . The first and second ports will trigger corresponding relay.