<Shower Mode>
<Low Splash Foaming Mode>
・
Press the switch on the side
with the protrusion.
・
Press the switch on the flat side.
Water Discharge
Outlet
■
Using the Spa-shower head
Changing the selection switch position switches between Shower Mode and air Low Splash Foaming Mode.
Shower head
Selection switch
Sprinkling filter unit
Foaming water outlet
Protrusion
16
Caution
Seat portion
3rd
layer
1st
layer
2nd
layer
Velcro
L
eg r
es
t por
tion
Velcro
Rotating bracket
①
Remove the leg rest cushion.
(Held with Velcro)
②
Remove the first layer of the seat cushion.
(Held with Velcro)
③
Push in the cylinder lever, and move
the backrest position.
Insert a flat-head screwdriver between
the cylinder lever and the rotating bracket,
and push in the cylinder lever.
(When shampooing with the broken
wire,
recline the backrest to the fully reclined position.)
④
Attach the seat cushion again.
⑤
Attach the leg rest cushion again.
<
Emergency operation when the reclining pedal does not work
>
Manual Emergency Operation of the Backrest Reclining
※
Cylinder lever
※
Inser
t a f
la
t-he
ad
scr
ewdr
iv
er
.
Caution
Manual emergency operation cannot be
performed while customer is seated. It is a
procedure of emergency correspondence in
the case of performing a shampoo operation
in the state where a wire is broken and it
becames impossible to reclining the backrest
by reclining pedal.
Ensure to bring the backrest to a fully
reclined position before guiding customer to
the seat, and be sure to support the
customer’s head when guiding them to a
lying posture.
Shower head bracket
●
Do not discharge a strong water stream when the
shower head is in the shower head bracket. Failure to
take this precaution may result in system failure due
to spilled water or damage to the floor.
●
Return the shower head to the shower head bracket
after use so that the sprinkling filter unit is pointed
toward the basin.