background image

Consumable Supplies

The following parts are "consumable supplies" and wear, degradation, changes in external appearance and 

damage are expected.

Please note that repair or replacement of these parts is not covered by warranty, and a fee will be required.

(* The level and period of wear, degradation or damage may differ depending on the environment and 

conditions that the customer uses this product in.)

Inspections or replacement of parts will be required if there is extensive wear, degradation or damage.

Consumable Parts 
(The following parts are not covered by the warranty; the cost of replacement is your responsibility.)

 Neck cushion      

 Head pillow      

 Drain cap      

 Hair catcher     

 Mohair tape     

 Various rubber gasket     

 Shower hose

 Sponge    

 Shower head holder cover    

 Spa shower head foaming water part (foaming water outlet, rubber gasket)     

 Lubricant

oil

,

grease

,

etc

Furthermore, flaws, contamination, deterioration, and discoloration of the exterior parts below are not to be 
covered by the warranty.

 External parts

- Covers, frames, and basin;
- Upholstered parts (backrest, seat, armrest and back support

 

cushion etc);

- Other parts (shower head, shower head bracket, etc.).

If the product does not operate properly after checking and repairing the above points, stop using the product immediately.

Water does not come out.

Is the water stop valve of the 
pipe open?

Open the water stop valve. 

Before Requesting Repairs

27

 There is a sound when the 

    hot water is turned on.

 The temperature of the 

    hot water is low.

Does the sound change if the 
handle are pulled up or down 
to adjust the volume of water?

Is the set temperature of the 
water boiler appropriate?

Is the temperature set with the 
water stop handle appropriate?

Is hair blocked in the hair 
catcher?

Adjust the volume of water. 
(see page 16)

Adjust the set temperature of the water 
boiler to an appropriate temperature.

Adjust the set temperature to an appropriate 
level using the water stop handle. (see page 17)

Remove the hair trapped in the 
hair catcher. (see page 20)

 The water does not drain well.

If the wire is snapped

For replacement of broken wires, contact your closest 
dealer. Emergency operation to recline the backrest 
manually is available. (See page 15.)

If the following problems arise, conduct the checks outlined before requesting repairs.

Symptoms

Points to be checked

Solutions

The backrest does not recline.

 Is the wire snapped?

---

 The cover of the shower head 

holder came off

Attach the cover. (see page 13) When it 
becomes coming off easily, contact your closest 
dealer and replace the cover.

Is the sponge coming out of the 
net? (see page 13)

When you move the shower hose, a 

"squeak" sound is heard.

If the sponge comes out of the net, return it in 
the net. If the sponge fits in the net but makes a 
noise, replace the sponge. (see page 13)

Is the surface of the shower hose 
deteriorated and rough?
(The cover of the shower head holder 
and the shower hose rub against 
each other and make a noise)

If it is not solved by wiping the shower hose 
surface with a wet towel, contact your closest 
dealer and replace the shower hose.

Содержание YUME-iXi

Страница 1: ...contained in this booklet should be thoroughly read and understood before use Using this product before reading this operating manual may result in an accident This product is an industrial shampoo u...

Страница 2: ...s for Use and Precautions for Handling Synthetic Leather will be responsible for any damage or risk incurred Detailed descriptions of symbols are provided below Read and understand these symbols thoro...

Страница 3: ...or damage leading to injury Do not climb on parts such as the basin armrest or backrest Do not climb on pull or apply excessive force to parts such as the basin armrest back rest or footrest Failure t...

Страница 4: ...s head by hand when lowering or lifting the backrest Failure to follow this instraction may cause injury Do not use this product with the cover broken Do not use this product if the plating is peeling...

Страница 5: ...hing hair Do not drink the hot water The water quality may cause diarrhea or stomach pain 5 Do not wash tools such as scissors with a shampoo basin There is a possibility that it may be injured when t...

Страница 6: ...g mainly caustic soda NaOH or caustic potash KOH to clean the drain pipe Never pour thinners alcohol nail polish remover gasoline or kerosene into the drain Failure to follow this instruction may caus...

Страница 7: ...ter Failure to follow this instruction may cause water leaks Do not hit the cover with objects or kick the cover Failure to follow this instruction may cause malfunctions or accidents leading to damag...

Страница 8: ...of the leather surface Placing heavy objects for a long period of time may leave an imprint or wrinkles on the synthetic leather that cannot be removed Precautions for Handling Synthetic Leather Handl...

Страница 9: ...film applied to the surface that may crack or peel due to corrosion or aged deterioration Flaws or cracks may occur on the plated surface due to impacts from falling objects Flaws or cracks may occur...

Страница 10: ...mrest Shower head Step Basin Back support cushion Seat Legrest seat portion Seat Legrest legrest portion Armrest plate Neck device Trap cover Basin center cover Reclining pedal H type Maintenance cove...

Страница 11: ...shampooing from the back back position Precaution for Basin This product employs a ceramic basin Since bending or deformation cannot be avoided when forming the basin the position height or shape of...

Страница 12: ...e the fastening pins The short edge faces the basin side The long edge faces the seat side Remove neck cushion Caution Preparations Neck cushion Metal fitting Snap button Fastening pin Basin side Seat...

Страница 13: ...ead bracket and the cover Align groove in the cover and protrusion of the holder until they snap into place Protrusion Sponge Cover Sponge holder Shower head bracket Do not remove the cover of bracket...

Страница 14: ...krest is reclined may cause them to bump their back into the basin which may result in injury When pressing the reclining pedal hold the customer s head with your hand and release the lock Have the cu...

Страница 15: ...and outside the basin Moisture collected in the water collection pan of the basin center cover 10 After using the product wipe off any moisture Drain cap Basin center cover 6 7 9 8 Shampoo the hair Af...

Страница 16: ...ion Attach the seat cushion again Attach the leg rest cushion again Emergency operation when the reclining pedal does not work Manual Emergency Operation of the Backrest Reclining Cylinder lever Inser...

Страница 17: ...or accidentally trickle due to an increase in water pressure at night This may cause water to spill from the basin leading to water leakage If the drainage become sluggish the drainpipe may be clogged...

Страница 18: ...lated surface of the water stop handle If the plating is peeled off immediately stop using the product and contact your closest dealer Continued operation may result in personal injury Adjusting the w...

Страница 19: ...mall amount of water may flow out which does not affect use If the decreasing level is significant the gasket of the drain cap may have deteriorated or become worn Replace the drain cap Available at a...

Страница 20: ...being locked then if the neck device should come loose while shampooing the customer may bump their head resulting in injury Remove the head pillow Rotate the head pillow as in the illustration below...

Страница 21: ...w this instruction may cause scratches or discoloration Thinner Wax Chemicals Alcohol Kerosene Abrasive Maintenance Reclining pedal Cover Hair catcher Drain cap Hair catcher Pull out the hair catcher...

Страница 22: ...s water stain in the shower holes on the sprinkling filter unit with a toothbrush 3 Clean the foaming water outlet with water Clean the unit once a month as a general guide Remove dirt such as water s...

Страница 23: ...ossible with a 10 detergent solution diluted using water to avoid further staining by the plasticizing agent Take care to remove all water after wiping with a damp cloth Any water that remains may enc...

Страница 24: ...en the product is not in use If the cap is not detached the cap may accidentally close and the water may overflow the basin from the failure to notice water discharge thus resulting in water leaks Dra...

Страница 25: ...n the sponge every day After cleaning the sponge put it in the hose and put it back on the cover Remove the shower head The figure on the right Remove the cover from the shower hose 1 2 Install a new...

Страница 26: ...arts for the standard usage conditions for each product This is not the warranty period Daily Inspections To ensure that this product can be used for a long period of time follow the procedures outlin...

Страница 27: ...s turned on The temperature of the hot water is low Does the sound change if the handle are pulled up or down to adjust the volume of water Is the set temperature of the water boiler appropriate Is th...

Страница 28: ...hen disposing of this product or replaced parts adhere to the effective regulations and dispose of them appropriately After sales Service To request after sales service contact your closest dealer or...

Страница 29: ...alve Water mixing valves Operating environment Operating temperature 50 104 Operating humidity 95 or below No condensing Product See the Product Dimensions on page 28 Maximum reclining angle 42 Backre...

Страница 30: ...Hot water supply position Water supply position Drain position Wall surface or furniture Wall surface or furniture Step front back slide Figures shown above are for seating a customer about 170cm in...

Страница 31: ...rly Feed the hot water and visually check that water is discharged normally from the shower head water is not leaking from the air bubble fixture or the hot water is not turbid If hot water is not fed...

Страница 32: ...operly Open the water stop handle and check if warm water is output properly and that there is no abnormal noise then close the water stop handle and check that warm water stops properly An abnormal n...

Страница 33: ...33 MEMO...

Страница 34: ...34 MEMO...

Страница 35: ...35 MEMO...

Страница 36: ...36 1E043XA0 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan 101 Belmont Drive Somerset NJ 08873 800 526 3847 TAKARA BELMONT CORPORATION Book Number U S A JAPAN...

Отзывы: