Page 10 of 20
TN-906-AN
© Tait Electronics Limited 21 December 2005
3.
Set up the parameters in the Connection tab as usual (use the online
Help if required).
4.
In the Port Switch tab, select the
Port switch
check box.
5.
In the
Connect command
field, enter ^M/Cx^M.
This means:
Note
Use the ^ (carat) symbol to instruct the Service Kit that this is a
control character.
Do not
use the control key.
6.
In the
Connect response
field, enter 1.
7.
In the
Disconnect command
field, enter ^Mxxx^M/X^M.
This means:
8.
In the
Disconnect response
field, enter 3.
^M
instructs the APS to enter command mode
a
a. This is equivalent to the carriage return character.
/C
requests a connection
x
the port number of the base station you wish to connect to
^M
terminates the sequence
^M
instructs the APS to enter command mode
xxx
three instances of the logoff character
a
a. This must match the logoff character chosen when setting up the modem (L
was chosen in this case). Refer to
“Common Configuration for all Ports” on
^M
terminates the sequence
/X^M
exits command mode