3.4.2 Connection
3.4.2.1 Connecting to the CMU or the EMU
The HCS-4838 series congress unit is equipped with a
1.5-meter 8P-DIN cable with a standard male
connector. When connecting the HCS-4800CMU/
HCS-8600EMU to the contribution units, just connect
the male connector of the first unit to the output of the
main unit.
Figure 3.4.2 HCS-4838 series congress unit connected
to the CMU/EMU
For a longer distance between the contribution unit and
the CMU/EMU, a CBL8PS extension cable can be
used. One end of this cable is equipped with a 8P-DIN
male connector, the opposite end is equipped with a
female connector. Just connect the female connector of
the cable to the contribution unit, and connect the male
connector to the output of the main unit. The Cat5e
cable can also be used as an extension cable, one end
of the Cat5e cable is connected to output of the main
unit via the CBL8P2RJ45S converter cable; the other
end of the Cat5e cable is connected to the 8P-DIN
male connector of the contribution unit via the
CBL8S2RJ45S converter cable.
Figure 3.4.3 HCS-4838 series congress unit connected
to the CMU/EMU
Neither the replacement of congress units nor cable
faults between congress units will affect the other units
if “Closed Loop - Daisy Chain”
connection topology is
selected. “Closed Loop - Daisy Chain” connection,
achieved by closing the loop of the daisy-chained units,
increases system reliability. For “Closed Loop - Daisy
Chain” ring connection, HCS-8600MCLS Loop switcher
is needed. The "TO MU" port of HCS-8600MCLS is
connected to the output of the main unit via
CBL8P2RJ45 converter cable; the other port of
HCS-8600MCLS is connected to the contribution unit
via CBL8P2RJ45 converter cable; at last, connect the
last contribution unit back to the CMU via a CBL8PS
extension cable.
Figure 3.4.4 “Closed Loop - Daisy Chain” connection
between the CMU and HCS-4838 series congress units
3.4.2.2 Connection between congress units
All congress units of HCS-4800 system are
daisy-chained easily and conveniently by dedicated
8P-DIN cables.
When connecting to another congress unit, just
connect the 8P-DIN standard female connector on the
0.6-meter cable of the unit to the 8P-DIN standard male
connector on the 1.5-m 8P-DIN standard male
connector on the1.5-meter cable of the next unit.
78
Содержание HCS-4800 Series
Страница 55: ...Figure Microphone Test interface 41...
Страница 82: ...Figure 3 3 8 Dual backup microphone high end congress system solution 69...
Страница 84: ...Setting brightness Setting language Setting unit information 71...
Страница 100: ...Figure 3 5 6 Installation diagram of HCS 48U6SPK 87...
Страница 111: ...3 6 2 Installation 3 6 2 1 Cutout Figure 3 6 2 Cutout of HCS 48U9 80 series flush mounted congress unit unit mm 98...
Страница 112: ...Figure 3 6 3 Cutout of HCS 48U7M 80 flush mounted congress unit unit mm 99...
Страница 113: ...3 6 2 2 Installation Figure 3 6 4 Installation of HCS 48U7M 80 series flush mounted congress unit 100...
Страница 115: ...Figure 3 6 7 Disassembly caution of HCS 48U9 series flush mounted congress unit 102...
Страница 125: ...3 7 2 Installation Figure 3 7 2 Cutout of HCS 48U10 80 series congress unit unit mm 112...
Страница 126: ...Figure 3 7 3 Installation of HCS 48U10 80 series congress unit 113...
Страница 167: ...3 13 2 Installation Figure 3 13 2 Cutout of HCS 4857 series congress unit unit mm 150...
Страница 172: ...4 1 Functions and indications Front Side Bottom Figure 4 1 HCS 8685 Interpreter unit 154...
Страница 223: ...Dimension mm Note The height of the desk is reconmend above 710mm Color Black PANTONE 419 C Weight 3 1kg 202...
Страница 232: ...Appendix Custom made cable 211...