3.4.3 Operation
Before a meeting starts, the congress units need to be
configured by the operator, including: numbering and
testing. During the meeting, the participators can use
the congress unit to activate microphone, request to
speak, etc.
3.4.3.1 Delegate unit
We introduce all the operation of HCS-4838 series
congress units. The congress units of this series
feature one or more of these functions.
1. Number
First of all, make sure that all the congress units are
connected properly to the CMU. All congress units
must be numbered when the system is used for the first
time or when adding or replacing congress units. The
numbering function can be activated by application
software or main unit.
■ Press “Unit Numbering” on application software.
The system now goes to numbering status. At this
time, press the on/off key of each congress unit
one by one. Once all congress terminals
numbered, restart the CMU to update the number
information.
■ Rotate the function knob to select “0.5 Numbering”,
then select and press “start” .The LCD screen of
the main unit shows “Press key of DCS Units, one
by one and reboot EMU”; meanwhile, those
indicate light of connected congress units will
flashing; press on/off key of congress units one by
one; then reboot the main unit after all congress
units being numbered for updating .
2. Speaking
(without software)
Speaking mode is configured on the CMU (refer to
section 2.1.3).
A. “Open” mode
Active microphone number limitation (1~8)
NOT
reached
:
a. The microphone will be activated when the
microphone On/Off key is pressed
, t
he speaker
can give his/her speech
;
b. The microphone will be deactivated when the
microphone On/Off key is pressed again.
Active microphone number limitation (1~8)
reached
:
a. Press
the microphone On/Off key to request to
speak;
b. Press the microphone On/Off key again to cancel
the request to speak;
c. When an active microphone is turned off, the first
request microphone will be activated.
B. “Override” mode
Active microphone number limitation (1~8)
NOT
reached
:
a. The microphone will be activated when the
microphone On/Off key is pressed
, t
he speaker
can give his/her speech
;
b. The microphone will be deactivated when the
microphone On/Off key is pressed again.
Active microphone number limitation (1~8)
reached
:
If the delegate microphone On/Off key is pressed,
its microphone will be activated and the first
activated delegate microphone will be deactivated
at the same time to maintain the active
microphone number limitation. If the number of
active microphone (including chairman and VIP
unit) reaches 8, turning on another microphone will
switch off the delegate microphone which turned
on first.
C. “Voice” mode
Active microphone number limitation (1~8)
NOT
reached
:
a. The microphone On/Off key indicating light
remains on. When the delegate speaks into the
microphone at a short distance, the microphone
will be activated;
Note:
When numbering, please number the congress
units
one by one and do NOT press the
microphone On/Off button of several congress
units at the same time.
80
Содержание HCS-4800 Series
Страница 55: ...Figure Microphone Test interface 41...
Страница 82: ...Figure 3 3 8 Dual backup microphone high end congress system solution 69...
Страница 84: ...Setting brightness Setting language Setting unit information 71...
Страница 100: ...Figure 3 5 6 Installation diagram of HCS 48U6SPK 87...
Страница 111: ...3 6 2 Installation 3 6 2 1 Cutout Figure 3 6 2 Cutout of HCS 48U9 80 series flush mounted congress unit unit mm 98...
Страница 112: ...Figure 3 6 3 Cutout of HCS 48U7M 80 flush mounted congress unit unit mm 99...
Страница 113: ...3 6 2 2 Installation Figure 3 6 4 Installation of HCS 48U7M 80 series flush mounted congress unit 100...
Страница 115: ...Figure 3 6 7 Disassembly caution of HCS 48U9 series flush mounted congress unit 102...
Страница 125: ...3 7 2 Installation Figure 3 7 2 Cutout of HCS 48U10 80 series congress unit unit mm 112...
Страница 126: ...Figure 3 7 3 Installation of HCS 48U10 80 series congress unit 113...
Страница 167: ...3 13 2 Installation Figure 3 13 2 Cutout of HCS 4857 series congress unit unit mm 150...
Страница 172: ...4 1 Functions and indications Front Side Bottom Figure 4 1 HCS 8685 Interpreter unit 154...
Страница 223: ...Dimension mm Note The height of the desk is reconmend above 710mm Color Black PANTONE 419 C Weight 3 1kg 202...
Страница 232: ...Appendix Custom made cable 211...