3.8.2 Connection
3.8.2.1 Connecting to the CMU or the EMU
The HCS-4860/80 series congress unit is equipped
with a 1.5-meter 8P-DIN cable with a standard male
connector. When connecting the HCS-4800CMU/
HCS-8600EMU to the contribution units, just connect
the male connector of the first unit to the socket of the
CMU.
Figure 3.8.2 HCS-4860/80 series congress unit
connected to the CMU/EMU
For a longer distance between the contribution unit and
the CMU/EMU, a CBL8PS extension cable can be
used. One end of this cable is equipped with a 8P-DIN
male connector, the opposite end is equipped with a
female connector. Just connect the female connector of
the cable to the contribution unit, and connect the male
connector to the output of the main unit. The Cat5e
cable can also be used as an extension cable, one end
of the Cat5e cable is connected to output of the main
unit via the CBL8P2RJ45S converter cable; the other
end of the Cat5e cable is connected to the 8P-DIN
male connector of the contribution unit via the
CBL8S2RJ45S converter cable.
Figure 3.8.3 HCS-4860/80 series congress unit
connected to the CMU/EMU
Neither the replacement of congress units nor cable
faults between congress units will affect the other units
if “Closed Loop - Daisy Chain” connection topology is
selected. “Closed Loop - Daisy Chain” connection,
achieved by closing the loop of the daisy-chained units,
increases system reliability. To obtain “Closed Loop -
Daisy Chain” connection, just connect the last
congress unit back to the CMU or the EMU with a
CBL6PP extension cable (the cable features a
DIN-6PM connector at each end). In HCS-4800 series
system, the congress main unit can realize a “Closed
Loop - Daisy Chain” connection, but only one –
extension units do not offer this feature.
Figure 3.8.4 “Closed Loop - Daisy Chain” connection
between the CMU and HCS-4860/80 series congress
units
3.8.2.2 Connection between congress units
All congress units of HCS-4800 system are
daisy-chained easily and conveniently by dedicated
8P-DIN cables.
When connecting to another congress unit, just
connect the 8P-DIN standard female connector on the
0.6-meter cable of the unit to the 8P-DIN standard male
connector on the1.5-meter cable of the next unit.
123
Содержание HCS-4800 Series
Страница 55: ...Figure Microphone Test interface 41...
Страница 82: ...Figure 3 3 8 Dual backup microphone high end congress system solution 69...
Страница 84: ...Setting brightness Setting language Setting unit information 71...
Страница 100: ...Figure 3 5 6 Installation diagram of HCS 48U6SPK 87...
Страница 111: ...3 6 2 Installation 3 6 2 1 Cutout Figure 3 6 2 Cutout of HCS 48U9 80 series flush mounted congress unit unit mm 98...
Страница 112: ...Figure 3 6 3 Cutout of HCS 48U7M 80 flush mounted congress unit unit mm 99...
Страница 113: ...3 6 2 2 Installation Figure 3 6 4 Installation of HCS 48U7M 80 series flush mounted congress unit 100...
Страница 115: ...Figure 3 6 7 Disassembly caution of HCS 48U9 series flush mounted congress unit 102...
Страница 125: ...3 7 2 Installation Figure 3 7 2 Cutout of HCS 48U10 80 series congress unit unit mm 112...
Страница 126: ...Figure 3 7 3 Installation of HCS 48U10 80 series congress unit 113...
Страница 167: ...3 13 2 Installation Figure 3 13 2 Cutout of HCS 4857 series congress unit unit mm 150...
Страница 172: ...4 1 Functions and indications Front Side Bottom Figure 4 1 HCS 8685 Interpreter unit 154...
Страница 223: ...Dimension mm Note The height of the desk is reconmend above 710mm Color Black PANTONE 419 C Weight 3 1kg 202...
Страница 232: ...Appendix Custom made cable 211...