52
Operator´s manual round bale wrapper 7640
10.8.4 Overtip table (4)
First parameter indicates if the table shall return to horizontal
posistion after unloading.
0 = Table returns to horizontal position
1 = Table returns to loading position
Second paramter indicates if the loading arm shall be closed or
open after unloading.
0 = Loading arm open
1 = Loading arm closed
10.8.7 Type of film break sensor (7)
Parameter indicates if the fitted sensor is inductive or radio signal
RF = Radio frequency
Std = Inductive sensor
Operating model C
Value indicates the additional angle which the table shall move
after horizontal position is achieved. The table automatically
returns to wrapping position after the set value is reached.
10.8.5 Table and loading arm position after unloading (5)
10.8.6 Satellite start/stop parameters (6)
First parameter indicates start speed of the satellite (example
shows 40%).
Second parameter indicates max. speed (example shows 94%).
Third parameter indicates satellite speed before filmcutting (exam-
ple shows 45%).
The set value is related to the absolute extreme position of the
valve. . The oil flow is of course depending from the tractor pump
capacity.
Last parameter defines the start position of slow speed towards
cutter. This timer starts running at final passing of satellite stop
sensor. (example shows 9x50 ms).
10.8.8 Not in use (8)
Screen 8 is not displayed
Содержание 7640
Страница 2: ...2 Operator s manual round bale wrapper 7640...
Страница 13: ...13...
Страница 39: ...39 Operating model S...
Страница 71: ...71 Notes 13 Notes...