74
No sound when playing an
SACD, or DSD signals at
the USB input
Cause:
Only the
PCM
output of the
PDP 3000 HV
is connected to the amplifier.
Remedy 1:
Connect the
DSD
(All Format Out) output of the
PDP 3000 HV
to your amplifier,
and change the output configuration in the System Configuration menu to
DSD + PCM
.
Remedy 2:
Use separate cables for
DSD
and
PCM
playback, and connect the
DSD
(All
Format Out) output of the
PDP 3000 HV
to your amplifier as well. Change the
output configuration in the System Configuration menu to
DSD / PCM
.
Disc drawer fails to open
Cause:
Mechanical blockage, jammed disc, faulty disc mechanism.
Remedy:
Open the disc drawer by hand.
Before you do this, the device must be isolated from the mains supply: this is
accomplished by withdrawing
both
mains plugs. The disc drawer can now be
extended manually using a 4 mm allen key inserted in the opening in the back
panel (see illustration below): turn the allen key in the direction of the arrow
until the drawer is fully extended.
Drawer fails to open or
close when the Open/Close
button is operated.
Cause:
During the closing process the drawer was prevented from closing correctly,
typically by an obstacle, and this has triggered the safety coupling.
Remedy:
The drawer actuating system is fitted with a safety coupling which prevents
damage to the machine if a mechanical blockage should occur. If the safety
coupling is triggered, it can be re-engaged as described in Service Note 115.
Please contact a
service workshop.
Содержание PDP 3000 HV
Страница 2: ...2...
Страница 26: ...26...
Страница 39: ...39 English...
Страница 62: ...62...
Страница 78: ...78 Anschluss Schema Wiring diagram HV Link...
Страница 79: ...79 Anschluss Schema Wiring diagram externe Quellger te...
Страница 82: ...elektroakustik GmbH Co KG Herford Deutschland Germany...