E-mail: [email protected] or Fax: 01246 222 888
Page - 12 -
5.3 Alarm / Sequence
Press ‘MENU’ to go to the next page, the alarm menu.
Alarm / Sequence
Internal Buzzer
ON
Response Duration
10
Video Loss Alarm
Dis
Power ON detect
OFF
Sequence_1 Dwell
5
Sequence_2 Dwell
5
Sequence_3 Dwell
5
Load Installer Setting
5.3.1 Internal Buzzer
This allows you to activate or de-activate the audible buzzer on the unit when an alarm or
video loss has been detected. Use the left/right key to select ON/OFF.
5.3.2 Response Duration
This allows you to set up the duration of the alarm buzzer and alarm output signal when an
alarm has been detected. Use the Up/Down directional keys to change this value from
1~9999 seconds.
5.3.3 Video Loss Alarm
This allows you to enable or disable the Video Loss alarm facility on the multiplexer. When
on, Video Loss is considered as an alarm event.
5.3.4 Power ON Detect
This item allows you to enable/disable the camera auto-detection facility when the power is
ON. Use the left/right keys to select ON or OFF.
5.3.5 Sequence Dwell
Using the directional keys (
↑↓
↑↓
↑↓
↑↓
), you can use the cursor to select Sequence_1 Dwell, etc,
and the left/right keys (
←
←
←
←
→
→
→
→
) to change the sequence dwell time. This value can range from
1 to 255 seconds for each page (Full, quad, 3X3).
5.3.6 Load Installer Setting
This item allows you to reset the “Installer’s Configuration” from the on-board non-volatile
memory. Move the cursor to “Load Installer Setting” and press LIVE, this multiplexer will
reset to the original installer’s setting.