E-mail: [email protected] or Fax: 01246 222 888
Page - 20 -
5.9 VCR Menu
Press ‘MENU’ to go to the next page.
VCR Menu
Change Password
9999
VCR Source
BNC
Rec Time
24Hr
VCR Rec Mode
Field
Rec Density
Standard
Sync-Trig Edge
Fall
Playback Adjust
Auto
VCR Input Check
OFF
VCR Type
VCR
VCR Output
Normal
5.9.1 Change Password
The password can be changed to any four-digit number. Use the left/right keys to change
the existing password to your preferred number and press FUNC when finished. The
password will be saved into the non-volatile memory. If the user forgets this new password,
he can recall the factory password by using the Load Factory Password option. The default
factory password is 9999.
5.9.2 VCR Source
The multiplexer will accept two kinds of VCR input, one is BNC, the other is S-VHS (4 pin
mini-DIN). This must be selected according to the output and the cabling lead used from the
VCR.
5.9.3 Rec Time
Options are:
Real/ SYNC/ 4Hr/ 6Hr/ 8Hr/ 12Hr/ 18Hr/ 24Hr/ 28Hr/ 30Hr/
48Hr/ 72Hr/ 168Hr/ 240Hr/ 480Hr/ 720Hr / 960Hr
Real = Real Time Mode. The recording time depends on the length of tape. If you use 120
minutes of tape, you can record up to two hours using this mode.
SYNC = Synchronise the VCR with this multiplexer. To do this, the multiplexer’s VCR Trigger
signal must be connected with the VCR’s “SW OUT”. If your VCR can provide this signal, we
suggest you choose the SYNC option.
5.9.4 VCR Rec Mode
There are two options: Field and Frame.
5.9.5 Rec Density
This item allows you to select the recording density of the VCR. You may select