41
TROUBLESHOOTING GUIDE
the drip pan. The water will then drip onto the countertop or frame of the machine. This is normal.
•
Clean water under the machine indicates and internal leak. Have a technician perform further diagnos-
tics.
•
In the case of a large leak in which water is collecting in the machine frame or pooling significantly below
the machine, power down and unplug the machine and shut off the main water supply until a technician
has repaired the leak.
Vacuum Breaker:
•
When the machine is heating from cool and begins to build pressure from zero, it is normal for the vacu-
um breaker to sputter until the steam tank is near full pressure.
•
If sputtering occurs when the steam tank is near or at the set pressure, have a technician replace the vac-
uum breaker.
General Issues
Beeping Machine:
•
Low level alarm probe is not grounding out. Power cycle the machine. Ensure the tank is filling. Check for
adequate water flow to the machine. Have a technician perform further diagnostics.
Portafilter Stopping Point is Off
•
Under normal circumstances, when the portafilters are fully engaged the handle will face the barista. If
the portafilter stopping point is occurring before this point (handle points to the left), check that the
standard size 8.5 mm gaskets are being used and that the gasket is seated fully around the diffuser block.
•
If the portafilter stopping point is occurring after the normal point (handle points to the right), inspect
the
“
ears
”
of the portafilter for wear. If brass is showing on the ears, try using the taller 9mm gaskets.
Alternately, you can replace the portafilter head.
Pump/Motor is Making an Unusual Sound:
•
Make sure the water to the pump is fully on. Check the filters for clogs, change if needed. Check the wa-
ter lines for kinks.
•
Pump may be worn and in need of replacement.
High
-
Pitched Whistling Noise When Groups are Active:
•
Water is leaking out from the brew system. Check for VMUF0# error. Have a technician inspect the ex-
pansion valve and brew valve discharge for unusual flow.
Содержание S Series
Страница 12: ...12 INSTALLATION WORK STATION S200 ...
Страница 13: ...13 INSTALLATION WORK STATION S300 ...