38
TROUBLESHOOTING GUIDE
•
Have a technician perform further diagnostics.
An Individual Tank Reads LOW:
•
Have a technician perform further diagnostics.
An Individual Tank Reads Above the Set Point:
•
Have a technician perform further diagnostics.
Handheld Controller Display is Blank:
•
If the red power switch is in the ON position and is NOT lit, there is a lack of power to the machine. Check
the wall plug and circuit breaker.
•
If the red power switch is in the ON position and is lit, check that the lid of the electronics box is tightly
secured to the box. There is a safety interlock switch inside the box which interrupts power to the elec-
tronics when the lid of the electronics box is loose or removed.
•
Have a technician perform further diagnostics.
Shot Timers are Blank; Machine is Powered:
•
Have a technician perform further diagnostics.
Shot Timers are Cycling Through All Possible Indicators:
•
Shot timer is stuck in test mode. Have a technician inspect the timer board.
Steam Wand
Drip at the Steam Wand Tip:
•
A small amount of water will naturally drip as water condenses and accumulates in the wand between
uses. Make a habit of purging the steam wand of all accumulated liquids before and directly after steam-
ing a pitcher of milk.
•
Steam valve seal is worn. Have a technician perform a steam valve rebuild.
•
Steam valve is filled with milk residue. Have a technician inspect and clean the valve.
•
Steam actuator is engaging valve in off position. Actuator needs to be adjusted.
Wand is Hard to Move or Sticky:
•
Remove wand at the nut, clean and lubricate moving parts with food grade grease
Water Bubbles Out Around Wand Ball Pivot:
•
Wand ball o
-
ring is worn, replace with new Teflon o
-
ring from steam valve rebuild kit.
Weak Steam Pressure from Wand:
•
Steam valve not fully opening, steam handle needs to be adjusted
•
Steam tip is clogged. Clear steam tip of residue.
•
Steam valve is clogged. Have a technician inspect the valve.