27
This is the system clock screen.
Line 2 allows the operator to set the local time in a 24 hour format.
Line 3 and 4 allow the operator to set the current date.
The date and time are used for the error log. A small battery on the power board should keep the clock and
calendar running if the machine loses power, but it will need to be replaced eventually. Refer to the mark-
ings on the battery for replacement info.
Menu Level 2: System Clock
Menu Level 2: Heating Elements
The steam element requires a lot of power to heat. We split the load onto 2 parallel circuits, each with their
own relay, which can be deactivated independently here. This is useful for some troubleshooting.
Leave both lines in ACTIVE mode unless circumstances warrant.
You may also turn off the brew elements. This is helpful when cooling the machine or troubleshooting.
Leave the brew elements active under normal circumstances.