background image

 = The AUX output is enabled/disabled with the door opener button.

  The switching time of the AUX output can be programmed from 001 to 999 seconds 

(see section 8. q). When the switching time is set to “000”, the AUX output operates in 

toggle mode. Each press of the door opener button permanently activates or deacti-

vates the AUX output. When the AUX output is activated, the LED lights up red.

 = The AUX output is enabled/disabled by entering the AUX code or using a dedicated 

paired AUX transponder. 

  The switching time of the AUX output can be programmed from 001 to 999 seconds 

(see section 8. q). 

 

When the switching time is set to “000”, the AUX output operates in toggle mode. Each 

entry of the AUX code or each use of the AUX transponder permanently activates or 

deactivates the AUX output. 

 

When the AUX output is activated, the LED lights up red.

 

The AUX code and, if necessary, an AUX transponder must also be programmed, as 

described in section 8. r).

• 

The code lock will emit a long beep.

• 

Other settings can now be made, if desired. Press the   button to exit the programming 

mode.

Example 1: The AUX output is assigned a doorbell function (it is activated for a preset time by 

pressing the   button); for example, the switching time can be programmed to 8 seconds ac-

cording to section 8. q):

               

Example 2: The AUX output is assigned a tamper protection function (it is activated for a preset 

time when the code lock is detached from the wall or the light sensor on the back is exposed to 

light beams); the switching time can be programmed according to section 8. q):

               

67

Содержание 2388645

Страница 1: ...Bedienungsanleitung RFID Codeschloss Touch S Best Nr 2388645 Seite 2 40 Operating Instructions RFID code lock Touch S Item No 2388645 Page 41 79 ...

Страница 2: ...c Zugangsmodus wählen 14 d Standard Zugangscode ändern 15 e Transponder anlernen 16 f Benutzercode speichern ändern 17 g Alle Speicher löschen 18 h Einzelnen Speicher löschen 19 i Aufeinander folgende Speicher löschen 20 j Transponder löschen 21 k Aktivierungsdauer für den Umschaltkontakt einstellen 22 l Schutz vor Falscheingaben ein ausschalten 23 m Schutzfunktion auswählen 24 n Betriebsmodus wäh...

Страница 3: ...der speichern 31 t Alle Einstellungen auf die Werkseinstellung zurücksetzen 32 9 Bedienung 34 a Erstinbetriebnahme 34 b Zugang mittels gültigem Transponder Code 35 c Zugang per Türöffner Taste 35 10 Störungsbeseitigung 36 11 Wartung und Reinigung 39 12 Entsorgung 39 13 Konformitätserklärung DOC 39 14 Technische Daten 40 Seite 3 ...

Страница 4: ...alb diese Bedienungsanleitung zum Nachlesen auf Alle enthaltenen Firmennamen und Produktbezeichnungen sind Warenzeichen der jeweiligen Inhaber Alle Rechte vorbehalten Bei technischen Fragen wenden Sie sich bitte an Deutschland www conrad de Österreich www conrad at Schweiz www conrad ch 2 Symbol Erklärung Das Symbol mit dem Blitz im Dreieck wird verwendet wenn Gefahr für Ihre Gesund heit besteht z...

Страница 5: ... ist über eine Spannung von 12 24 V DC möglich Durch die besonders flache Bauweise ist die Montage auch an vielen schwierigen Einbauorten möglich da nur ein Loch für das Anschlusskabel erforderlich ist jedoch kein Gehäuseausschnitt oder ein Unterputzgehäuse Aus Sicherheits und Zulassungsgründen dürfen Sie das Produkt nicht umbauen und oder verändern Falls Sie das Produkt für andere Zwecke verwende...

Страница 6: ...rch einen elektrischen Schlag Beachten Sie die Sicherheitshinweise und Bedienungsanleitungen der übrigen Geräte an die das Produkt angeschlossen wird z B Türöffner Alarmanlage Wenn kein sicherer Betrieb mehr möglich ist nehmen Sie das Produkt außer Be trieb und schützen Sie es vor unbeabsichtigter Verwendung Der sichere Betrieb ist nicht mehr gewährleistet wenn das Produkt sichtbare Schäden aufwei...

Страница 7: ...der LED 1 und deren Funkti on ist in Kapitel 7 beschrieben Im Lieferumfang befindet sich ein kleiner Aufkleber mit Türklingel Symbol Wenn Sie die Türklingel Funktion für denAUX Ausgang verwenden möchten Kapitel 8 p kann damit die Taste überklebt werden siehe Pfeil im Bild rechts Im weiteren Verlauf der Anleitung wird jedoch davon ausgegangen dass die Taste nicht überklebt ist Dort ist deshalb imme...

Страница 8: ...kontakt wird bei einer gültigen Code Eingabe und oder einem gültigen Trans ponder aktiviert COM Mittelkontakt des Relais NO Schließerkontakt NO normally open im Ruhezustand geöffnet NC Öffnerkontakt NC normally closed im Ruhezustand geschlossen Der Anschluss ist abhängig davon welchen Türöffner Sie verwenden Fail Secure Türöffner Schließerkontakt NO COM Dieser Türöffner gibt den Verschluss riegel ...

Страница 9: ...schiedene Funktionen wählbar siehe Kapitel 8 p Schaltungsbeispiel 1 Netzteil 2 Türöffner Taste 3 Umschaltkontakt 4 AUX Ausgang 5 Fail Secure Türöffner übliche Bauart für Haustüren 6 Fail Safe Türöffner seltene Bauart z B für Fluchtweg Türen 7 Türkontakt z B Magnet Reedschalter Falls der Türöffner nicht über eine eingebaute Schutzdiode vor Spannungsspitzen verfügt so muss diese in der Nähe des Türö...

Страница 10: ...nd ein passendes Schrauberbit Durch die Form des Schraubenkopfs ergibt sich ein zusätzli cher Schutz vor Manipulationsversuchen Denken Sie daran dass der Lichtsensor auf der Rückseite nach der Montage im Dunkeln liegt montieren Sie das Codeschloss deshalb nicht auf durchsichtigen Oberflächen z B Acrylglas Fällt Licht auf den Lichtsensor so ist keine Bedienung über die Tasten mög lich Schließen Sie...

Страница 11: ...e Kapitel 8 a so liegt der Lichtsensor auf der Rückseite des Codeschlosses nicht im Dunkeln Kleben Sie diesen ggf mit einem Streifen un durchsichtigem Klebeband vorübergehend ab Beschreibung der LED Funktion LED Farbe Funktion LED leuchtet blau Das Codeschloss befindet sich im Standby Warten auf Transponder Tasteneingabe LED leuchtet gelb Der Programmiermodus ist aktiviert LED leuchtet grün Der Um...

Страница 12: ...er Transponder spei chern siehe Kapitel 8 s Anstelle der 2maligen Eingabe des Mastercodes über das Tastenfeld halten Sie den Master Transponder einmal in geringem Abstand vor den RFID Sensor um den Programmiermodus zu starten nicht möglich wenn der Mas tercode geändert werden soll hierzu ist aus Sicherheitsgründen ausschließlich das Tastenfeld zu verwenden Anschließend leuchtet die LED gelb und da...

Страница 13: ...e in Kapitel 8 g beschrieben alle Transponder Benutzercodes Gehen Sie wie folgt vor Starten Sie den Programmiermodus wie in Kapitel 8 a beschrieben durch zweimalige Einga be des Mastercodes die gelbe LED muss nun leuchten Wichtig Wenn Sie einen Master Transponder gespeichert haben so kann dieser aus Sicher heitsgründen nicht benutzt werden um den Programmiermodus für die Änderung des Mastercodes z...

Страница 14: ...Sie anschließend den gewünschten Zugangsmodus aus Transponder oder Eingabe des Standard Zugangscodes dieser ist für alle Benutzer gleich Programmierung siehe Kapitel 8 d Nur Transponder Transponder und zugehöriger Benutzercode dieser muss für jeden Benutzer separat gespeichert werden Das Codeschloss gibt ein langes Tonsignal zur Bestätigung aus Falls gewünscht können Sie jetzt weitere Programmieru...

Страница 15: ...sein In der Grundeinstellung ab Werk lautet der Standard Zugangscode 3333 Haben Sie einen 5 8stelligen Mastercode programmiert so verlängert sich diese Zahlenreihe entsprechend z B 5stelliger Mastercode Standard Zugangscode 33333 Gehen Sie wie folgt vor Starten Sie den Programmiermodus wie in Kapitel 8 a beschrieben durch zweimalige Einga be des Mastercodes die gelbe LED muss nun leuchten Geben Si...

Страница 16: ...ls 3 schnelle Ton signale aus Ein versehentliches Überschreiben eines Speichers wird damit verhindert um auf dem gleichen Speicher einen anderen Transponder anzulernen muss der entsprechende Speicher zuerst gelöscht werden Anstatt den Transponder vor den RFID Sensor zu halten können Sie auch die 10stel lige Transponder Nummer eingeben bei Transponderkarten ist diese in der Regel auf einer Seite au...

Страница 17: ...code der voreingestellte Benutzercode für jeden Speicher lautet 88888 Gehen Sie wie folgt vor Beachten Sie dass hierzu der Programmiermodus nicht aufgerufen werden darf Dies hat den Sinn dass ein Benutzer seinen eigenen geheimen Benutzercode selbst spei chern ändern kann Drücken Sie 2x nacheinander die Taste Halten Sie den Transponder für den Sie einen Benutzercode speichern wollen in geringem Abs...

Страница 18: ... Benutzercode für jeden Speicher lautet 88888 Gehen Sie wie folgt vor Starten Sie den Programmiermodus wie in Kapitel 8 a beschrieben durch zweimalige Einga be des Mastercodes die gelbe LED muss nun leuchten Geben Sie den Programmiercode für den Löschvorgang ein Das Codeschloss gibt 2 Tonsignale aus Geben Sie den Code für den Löschvorgang ein Geben Sie den Code für das Löschen aller Speicher ein Z...

Страница 19: ...zercode geändert werden der Transponder bleibt gespeichert so gehen Sie wie in Kapitel 8 f beschrieben vor Gehen Sie wie folgt vor Starten Sie den Programmiermodus wie in Kapitel 8 a beschrieben durch zweimalige Einga be des Mastercodes die gelbe LED muss nun leuchten Geben Sie den Programmiercode für den Löschvorgang ein Das Codeschloss gibt 2 Tonsignale aus Geben Sie den Code für den Löschvorgan...

Страница 20: ...vor Starten Sie den Programmiermodus wie in Kapitel 8 a beschrieben durch zweimalige Einga be des Mastercodes die gelbe LED muss nun leuchten Geben Sie den Programmiercode für den Löschvorgang ein Das Codeschloss gibt 2 Tonsignale aus Geben Sie den Code für den Löschvorgang eines Speicherbereichs ein Geben Sie den Speicherbereich ein der gelöscht werden soll Nummer des ersten Speichers Stern Taste...

Страница 21: ...Sie den Transponder den Sie löschen wollen in geringem Abstand vor den RFID Sensor Ist der Transponder bereits gelöscht oder unbekannt gibt das Codeschloss 3 schnelle Tonsignale ab Anstatt den Transponder vor den RFID Sensor zu halten können Sie auch die 10stel lige Transponder Nummer eingeben bei Transponderkarten ist diese in der Regel aufgedruckt Falls gewünscht lassen sich nun weitere Transpon...

Страница 22: ...ch zweimalige Einga be des Mastercodes die gelbe LED muss nun leuchten Geben Sie den Programmiercode für die Aktivierungsdauer ein Das Codeschloss gibt 2 Tonsignale aus Geben Sie die gewünschte Zeit ein für die der Umschaltkontakt aktiviert werden soll Beispiel 1 Aktivierungsdauer 8 Sekunden Beispiel 2 Toggle Betrieb Das Codeschloss gibt ein langes Tonsignal zur Bestätigung aus Falls gewünscht kön...

Страница 23: ...ie wie folgt vor Starten Sie den Programmiermodus wie in Kapitel 8 a beschrieben durch zweimalige Einga be des Mastercodes die gelbe LED muss nun leuchten Geben Sie den Programmiercode für den Schutz vor Falscheingaben ein Jeder Aufruf des Programmiercodes wechselt zwischen Schutz eingeschaltet und Schutz ausgeschaltet hin und her Das Codeschloss gibt ein langes Tonsignal zur Bestätigung aus Falls...

Страница 24: ...s gibt 2 Tonsignale aus Wählen Sie die gewünschte Schutzfunktion aus Nach der Eingabe von 20 aufeinander folgenden falschen Zahlen die zu keinem ge speicherten Code passen wird ein Warnton ausgegeben und das Codeschloss sperrt das Tastenfeld für die Dauer von 30 Sekunden Nach der Eingabe von 5 falschen Codes wird ein Warnton ausgegeben und das Code schloss sperrt das Tastenfeld für die Dauer von 3...

Страница 25: ...s Wählen Sie den gewünschten Betriebsmodus aus Normalmodus Der Umschaltkontakt wird per Transponder und oder Benutzercodes geschaltet Bypass Modus Zusätzlich zu allen Funktionen des Normalmodus ist der Bypass Code aktiv Nach der Eingabe des Bypass Codes Programmierung siehe Kapitel 8 o wird der Um schaltkontakt dauerhaft aktiviert Gültige Transponder Benutzercodes haben nun keine Steu erfunktion m...

Страница 26: ...ielsweise einen 5stelli gen Mastercode programmieren so muss auch der Bypass Code 5stellig sein Gehen Sie wie folgt vor Starten Sie den Programmiermodus wie in Kapitel 8 a beschrieben durch zweimalige Einga be des Mastercodes die gelbe LED muss nun leuchten Geben Sie den Programmiercode für die Programmierung des Bypass Codes ein Das Codeschloss gibt 2 Tonsignale aus Geben Sie anschließend den Byp...

Страница 27: ...erbrochen ist bleibt auch der AUX Ausgang aktiviert Die LED blinkt in diesem Fall abwechselnd gelb und rot Der AUX Ausgang wird für eine bestimmte Zeit aktiviert wenn die Schutzfunktion siehe Kapitel 8 l ausgelöst hat Während der AUX Ausgang aktiviert ist leuchtet die LED rot Programmieren Sie im Anschluss die Schaltdauer für den AUX Ausgang siehe Kapi tel 8 q Diese darf nicht 000 sein andernfalls...

Страница 28: ...Sie im Anschluss die Schaltdauer für den AUX Ausgang siehe Kapi tel 8 q möglich sind 001 999 Sekunden Bei Programmierung von 000 als Schaltdauer arbeitet der AUX Ausgang im Toggle Betrieb bei jeder Eingabe des AUX Codes oder der Verwendung des AUX Trans ponders wird der AUX Ausgang dauerhaft aktiviert oder deaktiviert Bei aktiviertem AUX Ausgang leuchtet die LED rot Außerdem ist natürlich auch der...

Страница 29: ...8 a beschrieben durch zweimalige Einga be des Mastercodes die gelbe LED muss nun leuchten Geben Sie den Programmiercode für die Schaltdauer des AUX Ausgangs ein Das Codeschloss gibt 2 Tonsignale aus Geben Sie die gewünschte Zeit ein für die der AUX Ausgang aktiviert werden soll Beispiel 1 Aktivierungsdauer 8 Sekunden Beispiel 2 Toggle Betrieb Das Codeschloss gibt ein langes Tonsignal zur Bestätigu...

Страница 30: ...us dem Codeschloss gelöscht Gehen Sie wie folgt vor Starten Sie den Programmiermodus wie in Kapitel 8 a beschrieben durch zweimalige Einga be des Mastercodes die gelbe LED muss nun leuchten Geben Sie den Programmiercode für den AUX Code ein Das Codeschloss gibt 2 Tonsignale aus Geben Sie anschließend den AUX Code ein Dieser überschreibt einen evtl vorhandenen alten AUX Code Beispiel Das Codeschlos...

Страница 31: ...Master Transponder kann nicht zum Aufruf des Programmiermodus für die Ände rung des Mastercodes siehe Kapitel 8 b verwendet werden Hierzu ist ausschließ lich das Tastenfeld zu verwenden Gehen Sie wie folgt vor Starten Sie den Programmiermodus wie in Kapitel 8 a beschrieben durch zweimalige Einga be des Mastercodes die gelbe LED muss nun leuchten Geben Sie den Programmiercode für den Master Transpo...

Страница 32: ...speicherten Be nutzercodes einzugeben Programmieren Sie deshalb nach dem Zurücksetzen einen neuen Mastercode der die gleiche Länge hat wie vorher Alternativ löschen Sie nach dem Zurücksetzen alle Speicher der Transponder Benut zercodes siehe Kapitel 8 g Gehen Sie in folgenden Schritten vor Trennen Sie das Codeschloss von der Spannungs Stromversorgung und warten Sie bis die LED erloschen ist Betäti...

Страница 33: ...d 3333 Aktivierungsdauer für Umschaltkontakt 8 k 5 Sekunden Schutz vor Falscheingaben 8 l ausgeschaltet Schutzfunktion 8 m 20 falsche Ziffern Betriebsmodus 8 n Normal Bypass Code 8 o Funktion für AUX Ausgang 8 p 7 Schaltdauer für AUX Ausgang 8 q 000 Toggle Betrieb AUX Transponder 8 r AUX Code 8 r Master Transponder 8 s 33 ...

Страница 34: ...n vorzugehen Bereiten Sie sich eine Tabelle vor in der Sie alle Einstellungen Benutzer Transpondernum mern und Codes speichern Überlegen Sie sich einen Mastercode 4 8stellig und programmieren Sie ihn siehe Kapitel 8 b Beachten Sie dass alle Codes Mastercode Benutzercodes Standard Zugangs code Bypass Code AUX Code die gleiche Länge haben müssen Bei nachträglicher Änderung der Stellenzahl für den Ma...

Страница 35: ...llte Zeit aktiviert die LED leuchtet grün Das Öffnen der Tür wird durch das Codeschloss per Türkontakt erkannt Die LED blinkt ab wechselnd grün blau bei gleichzeitig aktiviertem AUX Ausgang grün rot Während dieser Zeit ist keine andere Funktion möglich Nachdem die Tür wieder geschlossen wurde leuchtet die LED blau bei gleichzeitig aktiviertem AUX Ausgang rot AUX Ausgang Nachdem das Codeschloss ein...

Страница 36: ...steht offen In diesem Fall ist keine Programmierung möglich Schlie ßen Sie die Tür Keine Bedienung über die Tasten möglich es wird kein Code angenommen Der Lichtsensor auf der Rückseite des Codeschlosses liegt nicht im Dunkeln Kleben Sie diesen ggf mit einem Streifen undurchsichtigem Klebeband vorübergehend ab Der Türöffner schaltet nicht Der Umschaltkontakt ist potentialfrei Das bedeutet Sie müss...

Страница 37: ...pielsweise einen 5stelligen Mastercode pro grammieren so müssen auch die Benutzercodes 5stellig sein In der Grundeinstellung ab Werk lautet der voreingestellte Benutzercode für jeden der 600 Speicher 8888 Haben Sie einen 5 8stelligen Mastercode programmiert so verlängert sich diese Zahlenreihe entsprechend z B 5stelliger Mastercode der voreingestellte Benutzer code für jeden Speicher lautet 88888 ...

Страница 38: ...odes aus Sicherheitsgründen nicht aufgerufen werden Geben Sie stattdessen wie in Kapitel 8 b beschrieben den alten Mastercode über das Tastenfeld 2x nacheinander ein um den Pro grammiermodus zu starten NachdemZurücksetzenaufdieWerkseinstellungensindTransponderundBenutzercodes nicht gelöscht Dies ist normal Sollen Transponder und Benutzercodes auch gelöscht werden so gehen Sie wie in Kapitel 8 g be...

Страница 39: ...ren nicht in den Hausmüll Entsorgen Sie das Produkt am Ende seiner Lebensdauer gemäß den geltenden gesetzlichen Bestimmungen Sie erfüllen damit die gesetzlichen Verpflichtungen und leisten Ihren Beitrag zum Umweltschutz 13 Konformitätserklärung DOC Hiermit erklärt Conrad Electronic SE Klaus Conrad Straße 1 D 92240 Hirschau dass dieses Produkt der Richtlinie 2014 53 EU entspricht Der vollständige T...

Страница 40: ...Relais Kontaktbelastbarkeit max 24 V DC 2 A Schaltdauer einstellbar 1 99 Sekunden oder Toggle Betrieb Grundeinstellung 5 Sekunden Ausgang 2 AUX Potentialfreier 1poliger Schaltkontakt Relais Kontaktbelastbarkeit max 24 V DC 2 A Schaltdauer einstellbar 1 999 Sekunden oder Toggle Betrieb Grundeinstellung Toggle Betrieb Speicher 600 für Transponder Benutzercode Montageort Innen Außenbereich Schutzgrad...

Страница 41: ...he access mode 53 d Changing standard access code 54 e Pairing transponder 55 f Saving changing user code 56 g Clearing all memory cells 57 h Clearing individual memory cells 58 i Clearing successive memory cells 59 j Deleting transponder 60 k Setting the changeover contact activation time 61 l Enabling disabling protection against incorrect entries 62 m Selecting protective function 63 n Selectin...

Страница 42: ...as master transponder 70 t Resetting all settings to factory defaults 71 9 Operation 73 a Getting started 73 b Accessing via valid transponder code 74 c Accessing via door opener button 74 10 Troubleshooting 75 11 Cleaning and maintenance 78 12 Disposal 78 13 Declaration of Conformity DOC 78 14 Technical data 79 42 ...

Страница 43: ...tructions Therefore retain these operating instructions for reference All company and product names contained herein are trademarks of their respective owners All rights reserved If there are any technical questions please contact www conrad com contact 2 Description of symbols The symbol with the lightning in the triangle is used if there is a risk to your health e g due to an electric shock The ...

Страница 44: ... and outdoor use IP65 A 12 24 V DC power supply can be used Thanks to its particularly flat design the product can also be installed in many difficult installation locations as only the connection cable requires a hole and the housing requires no cut out For safety and approval purposes do not rebuild and or modify this product Using the product for purposes other than those described above may da...

Страница 45: ... this can cause life threatening electric shock Always observe safety information and operating instructions for the other devices e g door opener alarm system to which the product is connected If it is no longer possible to operate the product safely stop using it and prevent unauthorised use Safe operation of the appliance can no longer be guaranteed if it shows visible signs of damage malfuncti...

Страница 46: ...unting Description of the colours of the LED 1 and their function can be found in section 7 A small sticker with a doorbell symbol is included If you want to assign the doorbell function to the AUX output sec tion 8 p attach a sticker to the button as shown by the arrow in the right picture These instructions assume that this button is used with out a sticker The button is therefore always shown a...

Страница 47: ...ngeover contact is activated by entering a valid code and or using a valid transponder COM Relay centre contact NO Normally open contact NO normally open NC Normally closed contact NC normally closed The connection depends on the door opener used Fail secure door opener normally open contact NO COM This door opener releases the locking latch when the operating voltage is present common design for ...

Страница 48: ... functions can be selected see section 8 p Wiring example 1 Power adapter 2 Door opener button 3 Changeover contact 4 AUX output 5 Fail secure door opener common design for entrance doors 6 Fail safe door opener uncommon design e g used for escape route doors 7 Door contact e g magnetic reed switch If the door opener has no built in protective diode against voltage surges it must be connected with...

Страница 49: ...o special screws and a matching screwdriver bit The screw head shape provides extra protection against attempted ma nipulations The light sensor on the back should be in the dark after installation Therefore make sure the code lock is not installed on transparent surfaces e g acrylic glass If the light sensor is exposed to light beams button operation is disabled The connection cables must be conn...

Страница 50: ...n 8 a the light sensor on the back of the code lock is exposed to light beams If necessary attach a non transparent tape to the light sensor LED function description LED colour Function LED lights up blue The code lock is in standby waiting for tran sponder key input LED lights up yellow The programming mode is activated LED lights up green The changeover contact is activated LED lights up red The...

Страница 51: ... s Other than entering the master code twice using the keypad you can also start the programming mode by holding the master transponder in front of the RFID sensor this option is not possible when the master code needs to be changed which means that the keypad is the only option for security reasons The programming mode is enabled when the LED lights up yellow and the code lock emits a long beep T...

Страница 52: ...sting 4 digit one you should delete all transponders user codes as described in section 8 g Proceed as follows Enter the master code twice to start the programming mode as described in section 8 a The yellow LED must light up Important If you have already saved a master transponder for security reasons you cannot use it to start the programming mode in order to change the master code You can only ...

Страница 53: ...access mode The code lock will emit 2 beeps Select the desired access mode transponder or standard access code the same applies for all users see programming in section 8 d only transponder transponder and respective user code a separate user code must be saved for each user The code lock will emit a long beep Other settings can now be made if desired Press the button to exit the programming mode ...

Страница 54: ... code must also have 5 digits By default the standard access code is 3333 The number of digits in the standard access code 5 to 8 digits depends on the number of digits in the master code for example if the master code has five digits the standard access code is 33333 Proceed as follows Enter the master code twice to start the programming mode as described in section 8 a The yellow LED must light ...

Страница 55: ... code lock emits three brief beeps Accidental overwriting of a memory cell is thus excluded the corresponding memory cell must first be cleared in order to pair a new transponder on the same memory cell Other than holding the transponder in front of the RFID sensor you can enter a 10 digit transponder number it is usually indicated on one side of a transponder card If desired other transponders ca...

Страница 56: ...umber of digits in the master code for example if the master code has five digits the preset user code is 88888 Proceed as follows Note that the programming mode cannot be called up for this purpose The point is that a user can save change their own secret user code themselves Press the button twice in a row Hold the transponder you want to save a user code for in front of the RFID sensor When the...

Страница 57: ... depends on the number of digits in the master code for example if the master code has five digits the preset user code is 88888 Proceed as follows Enter the master code twice to start the programming mode as described in section 8 a The yellow LED must light up Enter the programming code to enable deletion The code lock will emit 2 beeps Enter the code for deletion Enter the code for clearing all...

Страница 58: ...ot be overwritten by a new one If only the user code needs to be changed without deleting the transponder follow the instructions in section 8 f Proceed as follows Enter the master code twice to start the programming mode as described in section 8 a The yellow LED must light up Enter the programming code to enable deletion The code lock will emit 2 beeps Enter the code for deletion Enter the numbe...

Страница 59: ...he default user code is 88888 Proceed as follows Enter the master code twice to start the programming mode as described in section 8 a The yellow LED must light up Enter the programming code to enable deletion The code lock will emit 2 beeps Enter the code for deleting a memory cell group Enter the memory cell group to be cleared number of the first memory cell star key number of the last memory c...

Страница 60: ...ld the transponder to be deleted in front of the RFID sensor When transponder deletion is complete or transponder is unknown the code lock emits three brief beeps Other than holding the transponder in front of the RFID sensor you can enter a 10 dig it transponder number it is usually indicated on a transponder card You can also delete other transponders if desired by holding the transponder in fro...

Страница 61: ... the programming mode as described in section 8 a The yellow LED must light up Enter the programming code for the activation time The code lock will emit 2 beeps Enter the desired changeover contact activation time Example 1 Activation time is 8 seconds Example 2 Toggle mode The code lock will emit a long beep Other settings can now be made if desired Press the button to exit the programming mode ...

Страница 62: ... digits as described in section 8 m below Proceed as follows Enter the master code twice to start the programming mode as described in section 8 a The yellow LED must light up Enter the programming code to enable protection against incorrect entries Each time the programming code is entered the status changes between protection enabled and protection disabled The code lock will emit a long beep Ot...

Страница 63: ...to select the protective function The code lock will emit 2 beeps Select the desired protective function Successive entering of 20 incorrect digits that do not match any of the stored codes triggers an alarm and the code lock blocks the keypad for 30 seconds Entering the invalid code 5 times in a row triggers an alarm and the code lock blocks the keypad for 30 seconds The code lock will emit a lon...

Страница 64: ... to select mode The code lock will emit 2 beeps Select the desired mode Normal mode The changeover contact is enabled via transponder and or user codes Bypass mode The bypass code is active in addition to normal mode functionality Enter ing the bypass code permanently activates the changeover contact for programming see section 8 o Control functionality of valid transponders user codes is disabled...

Страница 65: ...e must have the same length For example if a master code consists of 5 digits the bypass code must also have 5 digits Proceed as follows Enter the master code twice to start the programming mode as described in section 8 a The yellow LED must light up Enter the programming code to programme bypass code The code lock will emit 2 beeps Then enter the bypass code it overwrites the existing bypass cod...

Страница 66: ...unction is triggered see section 8 l The LED lights up red when the AUX output is enabled The switching time of the AUX output can be programmed see section 8 q The switching time cannot be set to 000 otherwise the AUX output will not work The AUX output is activated for a preset time by pressing the button the AUX output can function as a doorbell an included small sticker with a doorbell symbol ...

Страница 67: ...h entry of the AUX code or each use of the AUX transponder permanently activates or deactivates the AUX output When the AUX output is activated the LED lights up red The AUX code and if necessary an AUX transponder must also be programmed as described in section 8 r The code lock will emit a long beep Other settings can now be made if desired Press the button to exit the programming mode Example 1...

Страница 68: ...ster code twice to start the programming mode as described in section 8 a The yellow LED must light up Enter the programming code to set the AUX output switching time The code lock will emit 2 beeps Enter the desired AUX output activation time Example 1 Activation time is 8 seconds Example 2 Toggle mode The code lock will emit a long beep Other settings can now be made if desired Press the button ...

Страница 69: ...e code lock automatically deletes the existing AUX transponder Proceed as follows Enter the master code twice to start the programming mode as described in section 8 a The yellow LED must light up Enter the programming code for the AUX code The code lock will emit 2 beeps Enter the AUX code It overwrites the existing AUX code if any Example The code lock will emit 2 beeps An AUX transponder can be...

Страница 70: ...aster transponder Important You cannot use the master transponder to start the programming mode in order to change the master code see section 8 b You can only use the keypad for this purpose Proceed as follows Enter the master code twice to start the programming mode as described in section 8 a The yellow LED must light up Enter the programming code for the master transponder The code lock will e...

Страница 71: ...ccess mode you need to enter only the first four digits of the saved user code After resetting set a new master code with the same number of digits You can also clear all memory cells with transponders or user codes after resetting see section 8 g Perform the following steps De energise the code lock and wait for the LED to go off Keep the door opener button pressed to connect the green cable with...

Страница 72: ...eover contact activation time 8 k 5 seconds Protection against incorrect entries 8 l switched off Protection function 8 m 20 incorrect digits Operating mode 8 n Normal Bypass code 8 o N A AUX output function 8 p 7 AUX output switching time 8 q 000 toggle mode AUX transponder 8 r N A AUX code 8 r N A Master transponder 8 s N A 72 ...

Страница 73: ...of a master code consisting of 4 to 8 digits and programme it see section 8 b Make sure all codes master code user codes standard access code bypass code AUX code have the same length If for example you want to use a 5 digit master code instead of the 4 digit one you should first reset the code lock to factory defaults section 8 t and then clear all user memory cells section 8 g Though the transpo...

Страница 74: ...f the AUX output is activated simultaneously You cannot activate any other function during this time As soon as the door has been closed the LED lights up blue or red if the AUX output is acti vated simultaneously AUX output Once the code lock has recognised a valid AUX transponder or AUX code the AUX output is activated for a preset time and the LED lights up red The LED lights up blue once the A...

Страница 75: ...taneously and the door remains open The code lock cannot be programmed in this case Close the door Button operation is disabled and no code is accepted The light sensor on the back of the code lock is exposed to light beams If necessary attach a non transparent tape to the light sensor The door opener doesn t work The changeover contact is potential free This means that you must use the appropriat...

Страница 76: ...ne before pairing another transponder on the same memory cell The user code does not work All codes master code user codes standard access code bypass code AUX code must have the same length For example if a master code consists of 5 digits the user codes must also have 5 digits By default the preset user code for each of the 600 memory cells is 8888 The number of digits in the preset user code 5 ...

Страница 77: ...r user transponders can be used to activate theAUX output Master code cannot be changed For security reasons you cannot use a master transponder to start the programming mode in order to change the master code You can start the programming mode by entering the old master code twice with a keypad as described in section 8 b Resetting to factory defaults does not delete any transponders and user cod...

Страница 78: ... waste At the end of its service life dispose of the product in accordance with applicable regulatory guidelines You thus fulfil your statutory obligations and contribute to envi ronmental protection 13 Declaration of Conformity DOC Conrad Electronic SE Klaus Conrad Straße 1 D 92240 Hirschau hereby declares that this product conforms to Directive 2014 53 EU Click on the following link to read the ...

Страница 79: ...single pole changeover contact relay Max contact rating 24 V DC 2 A Adjustable switching time 1 99 seconds or toggle mode 5 seconds by default Output 2 AUX potential free single pole switch contact relay Max contact rating 24 V DC 2 A Adjustable switching time 1 999 seconds or toggle mode toggle mode by default Memory cells 600 for transponders user code Mounting location indoors outdoors Protecti...

Страница 80: ...ch auszugsweise verboten Die Publikation entspricht dem technischen Stand bei Drucklegung Copyright 2021 by Conrad Electronic SE This is a publication by Conrad Electronic SE Klaus Conrad Str 1 D 92240 Hirschau www conrad com All rights including translation reserved Reproduction by any method e g photocopy microfilming or the capture in electronic data processing systems require the prior written...

Отзывы: