Settings
Default value
AB
Behaviour after power
failure
0 = Return to previous function
1 = Switch off
2 = Switch on
0
AC
Weekly cycle setting
0 = 5 days ide 2 days
identical
(Mo - Fr + Sa - Su)
1 = 6 days ide 1 day
individual
(Mo - Sa + Su)
2 = 7 days identical
(Mo - Su)
The correct day of the
week must be set for the
program to recognise the
start of the weekend. For
further information, see
“c) Setting the date and
time”.
0
AD
Restore all settings to
factory defaults.
Press and hold the time button (8)
for three to five seconds until all
elements on the display light up at
the same time. All system settings
are reset to the factory defaults.
Error codes
If the internal or external sensor is faulty, the display shows a corresponding error code and the
thermostat switches heating on until the fault is rectified.
Code Descriptions
Suggestion
E1
Internal sensor
error
Switch the thermostat off and contact technical support service
or other technical personnel.
E2
External
sensor error
Check the external sensor connection.
Switch the thermostat off and contact technical support service
or other technical personnel.
Care and cleaning
Do not use any aggressive cleaning agents, rubbing alcohol or other chemical
solutions, as these may damage the housing or impair the functioning of the device.
• Use a dry, lint-free cloth to clean the front panel.
• To prevent scratch marks, do not press too strongly on the surface when cleaning.
Activate button lock when wiping the front panel. Accidentally pressing the buttons
can cause unintended settings.
Disposal
Electronic devices are recyclable waste and must not be placed in household waste.
At the end of its service life, dispose of the product according to the relevant statutory
regulations. Remove any inserted batteries and dispose of them separately from the
product.
You thus fulfil your statutory obligations and contribute to environmental protection.
Specifications
Input voltage ......................................... 90 - 240 V/AC, 50/60 Hz
Max. switching capacity ........................ 3000 W (ohmic load)
2000 W (inductive load)
Contact load .........................................16 A, 250 V
Adjustable standard range ....................+5 to +35 °C
Temperature display .............................0 to +40 °C
Display precision ..................................0.5 ºC
Sensor ..................................................1x internal, 1x external
External sensor .....................................NTC (10 k) 1 %
Protection class ....................................IP20
Operating conditions ............................. +1 to +70 ºC, <85 % relative humidity
Storage conditions ................................ +1 to +70 ºC, <85 % relative humidity
Dimensions (W x H x D) .......................94 x 94 x 41.3 mm
Display size ..........................................Ø 52 mm
Length of sensor cable .........................2.5 m
Weight ..................................................139 g