Parameter setting
Page 51/55
SYCLOPE TERE’O Touch XL
®
Installation, starting, and programming instructions
4)
Timings
Pressing the « Timings » button opens the programming window.
Sensor polarization time:
This button is used to enter a sensor start delay between
0 and 480 minutes. During this time the alarms and dosing will
not be active. This delay is activated when the regulator is turned
on or when the flow detected by the Flow-Switch is restored if it
is installed.
Dosing time cycle:
This button is used to set the cycle time of the dosing
pump. This time is adjustable from 10 to 1800s. This time
corresponds to the reaction time of the basin between the
injection of product and the measurement of the product.
By setting 0 for the polarization time of the sensor, the function is deactivated and the sensor
will be active immediately.
5)
Calibration
Calibrations are determining operations for good working of the controller and best treatment
of the swimming pool!
A bad calibration could be dangerous for your health and your swimming pool.
It can cause corrosions and destruction of the swimming pool parts.
In any doubt about the procedure, contact our after-sale service!
A bad setting point could cause excessive consumptions of calories and harm the
environment!
Before carrying out the calibration of pH, Chlorine or Bromine measurements must be
performed with special equipment using chemical reagents.
This operation does not require the stop the recirculating pumps nor the removing sensors
from the measuring cell.
The chemical reagents for pH, Chlorine or Bromine measurements are not provided with the
controller.
To proceed an automatic calibration:
Recirculating circuit must work since several minutes
Displayed value must be stable
Dosing pumps must be stopped
Sensor must not be defective or disconnected
Settings
pH channel
Timings
Sensor polarization time
in minutes
2
120
Dosing time cycle
in seconde