Installation and connections
Page 25/55
SYCLOPE TERE’O Touch XL
®
Installation, starting, and programming instructions
Blue (Terminal block n°3): AA’ RS485
White (Terminal block n°4): BB’ RS485
Black (Terminal block n°5): GND RS485
Configuration: All switches on
"ON"
Please, contact us for more information on these products.
Respect the connection polarities of the bus.
We suggest using a USB/RS485 interface module to connect the
SYCLOPE
TERE’O Touch
®
controller
to your computer. Please consult the instructions of this converter for the connection.
Reference
Name
INF1021
USB => 485 Converter
The controllers can be chained by respecting the order of the cables (putting in parallel).
b)
Polarization and termination of the RS485 bus
The bus can be polarized from your device if needed.
To do this you have to switch both micro-switches on the
electronic card Pol. RS + (A) and Pol. RS- (B) on the ON
position.
If your device is the last of the line on the RS485 bus
you can switch the Term switch. RS ON to enable line
termination.
For safety reasons, it is imperative to cut the power supply of your
SYCLOPE TERE’O Touch
®
device before opening the case to switch the micro-switches!