Installation and connections
Page 17/55
SYCLOPE TERE’O Touch XL
®
Installation, starting, and programming instructions
7)
Primary power connection
SYCLOPE TERE’O Touch
®
has a switch-mode power supply. It can be powered by an
alternating voltage between 90V and 240V 50/60Hz.
►
Use a 3-point 1.5 mm
2
to wire the power supply
►
Strip the 3 wires on 7mm
►
Pass the 3-point cable through a cable gland
►
Connect the phase on L1 and the neutral on the N of the main terminal block X1
►
Connect the earth on the PL1 stud using an M4 eyelet terminal
►
Tighten the cable gland to seal
Your
SYCLOPE
TERE’O Touch
®
doesn’t have a power switch. So, it’s directly supplied
when it’s connected to the mains.
8)
Connections of control outputs
●
Self-powered relays outputs connection pH P3
The self-powered relays outputs P3 (Primary supply voltage = voltage available on P3) used for
pH parameter regulation.
►
Strip the 3 wires of the power cable of the dosing device on 7mm
►
Pass the 3-point cable through a cable gland
►
Connect the phase on
L1 (37)
and the neutral on
N (38)
of the P3 mains terminal
block
►
Connect the earth on
PE (39)
of the P3 mains terminal block
►
Tighten the cable gland to seal