background image

Doc: 

101547

-GB-2140

19

 

Bergvägen 7 | SE-341 32 Ljungby | Sweden • Tel +46 (0)372-156 00 | www.swepac.com

F82B
F92B

Transport locking for machine

B00033

During transportation: Secure the machine with straps 

according to the illustration above.

NOTICE. Secure the machine by the base plate and not the 

rubber-cushioned upper part.

Handling the battery pack

Note the following precautions when carrying the battery 

pack.

• To carry the battery pack, remove it from the specified 

device or battery charger.

• Hold the grip of the battery pack and grasp it firmly so 

your fingers do not slip from the grip.

• Do not swing the battery pack around or throw it.

When loading the battery pack in a vehicle, place it in a 

level location inside the vehicle or load bed, and secure it 

so it does not move. If there are regulations that stipulate 

transportation methods, such as requirements for storage 

in a specified storage case, then follow those regulations.

Also, note the following precautions when loading the 

battery pack into a vehicle.

• Remove the battery pack from the specified device or 

battery charger and protect it with cushioning material.

• Face the intake/exhaust port downward when loading 

and securing the battery pack, so rainwater does not get 

inside.

• Do not throw the battery pack into or out of the load bed 

of a vehicle.

• Avoid direct sunlight, and do not load or secure the 

battery pack in a location that can become very hot, such 

as in an enclosed vehicle.

• Do not stack battery packs when loading them.

• Do not place baggage on top of the battery pack and be 

careful that other baggage does not slide and collide with 

the battery pack.

When shipping by third parties (e.g.: by air transport or 

forwarding agency), special requirements on packaging 

and labelling must be observed. For preparation of the 

item being shipped, consulting an expert for hazardous 

material is required.

• Ship battery packs only when undamaged.

• Observe the possibility of more detailed national 

regulations.

Handling the battery charger

Remove any battery before transporting the battery 
charger.

CLEANING

Machine

• Remove the battery pack before using a hose or 

pressure washer for cleaning the machine.

• Do not spray water on the battery pack while cleaning 

the machine. Water entering the components may cause a 

malfunction.

• After cleaning wipe off the DC power unit with a clean 

dry cloth.

Battery

• Before cleaning the battery pack, remove it from the 

machine or the battery charger.

• If the battery pack and connector are dirty, wipe them 

off with a clean dry cloth.

Battery charger

• Before cleaning, always unplug the AC plug from the 

electric outlet.

• If the battery charger is dirty, wipe it off with a soft dry 

cloth.

STORAGE

Machine

• Before storing, remove the battery pack to prevent 

unintended operation.

• Store the machine on a level surface.

• Avoid storage areas with high temperature and high 

humidity, or environments with severe temperature 

changes. Keep away from direct sunlight and rain.

Battery pack

Inappropriate long-term storage can cause the battery 

pack to deteriorate quickly and it may become unusable.

• Before storing the battery pack, remove it from the 

machine or the battery charger, to prevent unintended 

operation.

• Storing the battery pack in a very warm location can 

cause the battery pack to deteriorate quickly. – Optimal 

storage at room temperature. See 

”TECHNICAL DATA” on 

page 24

 for the storage temperature range.

• Before putting the battery in long-term storage, refer to 

the following table to confirm whether the charge level of 

the battery pack is suitable for long-term storage.

• Also check the charge level of the battery pack once a 
year while it is in storage.

Содержание F 82B

Страница 1: ...F 82B F92B FOR A SOLID GROUND USER MANUAL IN ORIGINAL Doc 101547 GB 2140...

Страница 2: ...wer unit installed in the machine Do not use a non genuine battery pack Using a non genuine battery pack could damage itself and the DC power unit because of poor protection functions etc INTRODUCTION...

Страница 3: ...GNS 6 SAFETY INSTRUCTIONS 7 MACHINE SIGNS AND IDENTIFICATION 9 COMPONENT CONTROL LOCATIONS 10 MAINTENANCE 13 PRE OPERATION 14 FUNCTION OVERVIEW 15 OPERATION 15 CHARGING PROCEDURE 15 OPTIONS 17 TRANSPO...

Страница 4: ...OUR INFORMATION ON DC POWER UNIT ATTACHMENT DC power unit safety functions include a function 1 to safely turn off torque to the motor when a stop signal is sent from the START STOP switch and a funct...

Страница 5: ...its for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipme...

Страница 6: ...he belt drive when the machine is on to avoid injury and damage See the safety instructions in the manual As the sound pressure level at the operator s ears exceeds 80 dB A ear protectors must be used...

Страница 7: ...er property or the environment Battery pack safety Failure to follow the instructions below may result in excessive heat fire and or bursting explosion etc Do not heat or place into fire Do not use ch...

Страница 8: ...safety 1 Before using the battery charger read all instructions and cautionary markings on battery charger battery pack and product using battery pack 2 CAUTION To reduce risk of injury charge only D...

Страница 9: ...the battery charger to excessive physical shock such as by dropping or hitting it Do not use the battery charger to charge anything except Honda battery packs Use only authentic battery packs Chargin...

Страница 10: ...com F82B F92B COMPONENT CONTROL LOCATIONS 1 B00022 5 2 3 4 1 8 7 6 9 12 11 13 10 14 Handle 2 DC power unit 3 V belt wheel 4 Motor plate 5 Protective cover 6 V belt 7 Rubber damper 8 Base plate 9 Vibra...

Страница 11: ...2 3 4 5 1 POWER button 2 START STOP switch 3 POWER indicator green light 4 ALERT indicator yellow light 5 ERROR indicator red light Battery ALERT ERROR B00041 8 7 6 5 3 4 2 1 1 Grip 2 Intake port bot...

Страница 12: ...k 2 Battery tray 3 Battery connector cap 4 Power cable 5 Battery fastener 6 Battery fastener lever 7 Rubber support Battery charger B00043 4 5 6 9 8 1 2 7 7 7 3 1 Charging cable 2 Charging connector 3...

Страница 13: ...Power cables Check o Wires harness Check o 2 4 Battery fastener Check o Replace o o 2 Rubber support power unit Check o Replace o 2 Battery hook Check o Replace o 2 Rubber mount power unit Replace o...

Страница 14: ...is stable Dry and well ventilated location Optimal charging at room temperature Battery packs shall be charged at temperatures between 5 C 41 F and 30 C 86 F Pre operation checks for DC power unit Che...

Страница 15: ...e POWER indicator turns off Press the POWER button again to start the machine Checking the charge level of the battery pack While the machine is operating the charge level indicator lights or flashes...

Страница 16: ...he charging connector 4 to the battery connector 5 All the indicators on the battery charger and the battery pack light for about one second After that just the battery charger s POWER indicator light...

Страница 17: ...when working on asphalt Stop the water supply by turning the water tap clockwise B00044 2 6 5 1 3 4 Disassemble the water tank doing as follow Push the locking ring on the coupling 1 towards the water...

Страница 18: ...1 by pulling the motor 2 towards the operator side Tighten the four screws Reassembly the cover in the reverse order Check the condition of the four rubber dampers 3 regularly Replace damaged dampers...

Страница 19: ...on packaging and labelling must be observed For preparation of the item being shipped consulting an expert for hazardous material is required Ship battery packs only when undamaged Observe the possibi...

Страница 20: ...become unusable Charge the battery pack until from 1 to 3 charging level indicators are lit On Flashing Off Battery charger Before storing the battery charger remove the battery pack from the battery...

Страница 21: ...utton DC power unit becomes hot POWER indicator lights Stop using the machine and wait for the DC power unit to cool down ERROR indicator is lit Possible cause Solution Protection function is engaged...

Страница 22: ...for the battery pack problem connect the specified device and check if it works properly When the device works the battery pack can be used normally 1 indicator flashes Problem was detected Low voltag...

Страница 23: ...H H H B00030 F82B F92B Metric Imperial H 620 mm 24 8 in H1 990 mm 38 9 in H2 980 mm 38 5 in L 1070 mm 42 1 in L1 610 mm 24 in W 430 mm 500 mm 16 9 in 19 7 in Machine with standard handle L L W H H H B...

Страница 24: ...1 rpm Current 27 A Voltage 72 V Net power 1 8 kW 2 4 HP 2 4 PS 3 600 min 1 rpm Torque 5 6 N m 0 57 kgf m 3 600 min 1 rpm Voltage 72 V Set speed Rated speed 3 600 min 1 rpm Battery pack operating tempe...

Страница 25: ...for the DC Power Unit established by Honda for each country The warranty conditions apply to DC Power Unit failures caused by any manufacturing or specification problem The warranty does not apply to...

Страница 26: ...Doc 101547 GB 2140 26 Bergv gen 7 SE 341 32 Ljungby Sweden Tel 46 0 372 156 00 www swepac com F82B F92B NOTES...

Страница 27: ...rmity Manufacturer Swepac AB Bergv gen 7 34132 Ljungby 1 Category Vibratory plate 2 Type F82B F92B 3 Engine power 1 6 kW The product complies with the following directives 2006 42 EG 2000 14 EG 2004 1...

Страница 28: ...Bergv gen 7 SE 341 32 Ljungby Sweden Tel 46 0 372 156 00 www swepac com FOR A SOLID GROUND...

Отзывы: